Your browser doesn't support javascript.
loading
A serial optical frequency-domain imaging study of early and late vascular responses to bioresorbable-polymer sirolimus-eluting stents for the treatment of acute myocardial infarction and stable coronary artery disease patients: results of the MECHANISM-ULTIMASTER study.
Itoh, Tomonori; Otake, Hiromasa; Kimura, Takumi; Tsukiyama, Yoshiro; Kikuchi, Tatsuo; Okubo, Munenori; Hayashi, Takatoshi; Okamura, Takayuki; Kuramitsu, Shoichi; Morita, Takashi; Sonoda, Shinjo; Ishihara, Shozo; Kuriyama, Nehiro; Isshiki, Takaaki; Soeda, Tsunenari; Hibi, Kiyoshi; Shinke, Toshiro; Morino, Yoshihiro.
Afiliação
  • Itoh T; Division of Cardiology, Department of Internal Medicine, Iwate Medical University, 2-1-1, Idai-Dori, Yahaba-Cho, Siwa-Gun, Yahaba, Iwate, 028-3695, Japan. tomoitoh@iwate-med.ac.jp.
  • Otake H; Division of Cardiology, Department of Internal Medicine, Graduate School of Medicine, Kobe University, Kobe, Japan.
  • Kimura T; Division of Cardiology, Department of Internal Medicine, Iwate Medical University, 2-1-1, Idai-Dori, Yahaba-Cho, Siwa-Gun, Yahaba, Iwate, 028-3695, Japan.
  • Tsukiyama Y; Division of Cardiology, Department of Internal Medicine, Graduate School of Medicine, Kobe University, Kobe, Japan.
  • Kikuchi T; Division of Cardiology, Edogawa Hospital, Edogawa, Tokyo, Japan.
  • Okubo M; Department of Cardiovascular Medicine, Gifu Heart Center, Gifu, Japan.
  • Hayashi T; Department of Cardiology, Hyogo Prefectural Awaji Medical Center, Sumoto, Hyogo, Japan.
  • Okamura T; Department of Medicine and Clinical Science, Yamaguchi University Graduate School of Medicine, Ube, Japan.
  • Kuramitsu S; Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
  • Morita T; Division of Cardiology, Osaka General Medical Center, Osaka, Osaka, Japan.
  • Sonoda S; University of Occupational and Environmental Health, Kitakyusyu, Japan.
  • Ishihara S; Mimihara General Hospital, Sakai, Osaka, Japan.
  • Kuriyama N; Miyazaki Medical Association Hospital, Miyazaki, Miyazaki, Japan.
  • Isshiki T; Ageo Central General Hospital, Saitama, Japan.
  • Soeda T; Nara Medical University, Kashihara, Japan.
  • Hibi K; Division of Cardiology, Yokohama City University Medical Center, Yokohama, Kanagawa, Japan.
  • Shinke T; Division of Cardiology, Department of Medicine, Showa University, Tokyo, Japan.
  • Morino Y; Division of Cardiology, Department of Internal Medicine, Iwate Medical University, 2-1-1, Idai-Dori, Yahaba-Cho, Siwa-Gun, Yahaba, Iwate, 028-3695, Japan.
Cardiovasc Interv Ther ; 37(2): 281-292, 2022 Apr.
Article em En | MEDLINE | ID: mdl-33895962
ABSTRACT
The purpose of this study was to assess early and late vascular healing in response to bioresorbable-polymer sirolimus-eluting stents (BP-SESs) for the treatment of patients with ST-elevation myocardial infarction (STEMI) and stable coronary artery disease (CAD). A total of 106 patients with STEMI and 101 patients with stable-CAD were enrolled. Optical frequency-domain images were acquired at baseline, at 1- or 3-month follow-up, and at 12-month follow-up. In the STEMI and CAD cohorts, the percentage of uncovered struts (%US) was significantly and remarkably decreased during early two points and at 12-month (the STEMI cohort 1-month 18.75 ± 0.78%, 3-month 10.19 ± 0.77%, 12-month 1.80 ± 0.72%; p < 0.001, the CAD cohort 1-month 9.44 ± 0.78%, 3-month 7.78 ± 0.78%, 12-month 1.07 ± 0.73%; p < 0.001 respectively). The average peri-strut low-intensity area (PLIA) score in the STEMI cohort was significantly decreased during follow-up period (1.90 ± 1.14, 1.18 ± 1.25, and 1.01 ± 0.72; p ≤ 0.001), whereas the one in the CAD cohort was not significantly changed (0.89 ± 1.24, 0.67 ± 1.07, and 0.64 ± 0.72; p = 0.59). In comparison with both groups, differences of %US and PLIA score at early two points were almost disappeared or close at 12 months. The strut-coverage and healing processes in the early phase after BP-SES implantation were significantly improved in both cohorts, especially markedly in STEMI patients. At 1 year, qualitatively and quantitatively consistent neointimal coverage was achieved in both pathogenetic groups.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Stents Farmacológicos / Intervenção Coronária Percutânea / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Humans Idioma: En Revista: Cardiovasc Interv Ther Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Stents Farmacológicos / Intervenção Coronária Percutânea / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Humans Idioma: En Revista: Cardiovasc Interv Ther Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão