Your browser doesn't support javascript.
loading
Are self-reported and self-monitored adherence good proxies for reaching relevant plasma concentrations?: Experiences from a study of anti-depressants in healthy volunteers.
Larsen, Klaus Groes; Areberg, Johan; Åström, Daniel Oudin.
Afiliação
  • Larsen KG; Department of Biostatistics & Programming, H. Lundbeck A/S, Copenhagen, Denmark.
  • Areberg J; Department of PKPD Modelling & Simulation, H. Lundbeck A/S, Copenhagen, Denmark.
  • Åström DO; Department of Value Evidence Analytics, H. Lundbeck A/S, Copenhagen, Denmark.
Clin Trials ; 18(4): 505-510, 2021 08.
Article em En | MEDLINE | ID: mdl-33938259
ABSTRACT

BACKGROUND:

The use of electronic-based devices to measure and to improve adherence of subjects in clinical trials is increasing. AiCure has developed a mobile technology that is claimed to provide visual confirmation of drug ingestion. While there is evidence suggesting that including such self-monitoring device in a study increases adherence, the quality of the data produced by the device may be questionable. Can the mobile technology reliably distinguish whether a subject takes the study drug or not?

METHODS:

Adherence was calculated based on exposure, self-reporting and self-monitoring for subjects randomized to an anti-depressant. Levels of adherence and agreement between the three approaches were investigated based on calculation of proportions, two-way tables and receiver operating curves.

RESULTS:

A total of 214 subjects had measured concentrations of study drug at all three time points (end of weeks 3, 4 and 5), along with adherence data to define proportion of days adherent based on self-reporting and the self-monitoring instrument developed by AiCure. Self-reported adherence proportions were higher than self-monitored adherence proportions, although both were high (>90%). Neither self-reported and self-monitored adherence agreed with exposure-based adherence.

CONCLUSION:

Both self-reported and self-monitored adherence overestimated adherence. Neither the self-reported nor the self-monitored adherence measure reflected subjects' actual adherence. This prompts for cautiousness when interpreting either of them, and it underlines the need for thorough validation of electronic devices and software that claims to measure adherence. The AiCure instrument may not be able to reliably determine whether the subjects swallow the study medication.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Adesão à Medicação / Autorrelato / Antidepressivos Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Clin Trials Assunto da revista: MEDICINA / TERAPEUTICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Adesão à Medicação / Autorrelato / Antidepressivos Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Clin Trials Assunto da revista: MEDICINA / TERAPEUTICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca