Your browser doesn't support javascript.
loading
Ceramic Bearings Are Associated With a Significantly Reduced Revision Rate in Primary Hip Arthroplasty: An Analysis From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man.
Holleyman, Richard J; Critchley, Rebecca J; Mason, James M; Jameson, Simon S; Reed, Mike R; Malviya, Ajay.
Afiliação
  • Holleyman RJ; Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, United Kingdom.
  • Critchley RJ; Northumbria Healthcare NHS Foundation Trust, Wansbeck General Hospital, Ashington, United Kingdom.
  • Mason JM; Centre for Heath Economics at Warwick, Warwick Medical School, University of Warwick, Coventry, United Kingdom.
  • Jameson SS; The James Cook University Hospital, Middlesbrough, United Kingdom.
  • Reed MR; Northumbria Healthcare NHS Foundation Trust, Wansbeck General Hospital, Ashington, United Kingdom.
  • Malviya A; Northumbria Healthcare NHS Foundation Trust, Wansbeck General Hospital, Ashington, United Kingdom; Newcastle University, Newcastle upon Tyne, United Kingdom.
J Arthroplasty ; 36(10): 3498-3506, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34238620
BACKGROUND: Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings. METHODS: Adult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data. RESULTS: In total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for PJI was significantly lower with CoC (risk ratio 0.748, P < .001) and CoP (risk ratio 0.775, P < .001) compared to MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P < .001), respectively. All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P < .001) CONCLUSION: This study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Europa Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Europa Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido