Your browser doesn't support javascript.
loading
Bailout From Sinus Jailing: In-Series TAVR-in-TAVR to Avoid Coronary Flow Obstruction.
Casenghi, Matteo; Oliva, Omar A; Squillace, Mattia; Bellamoli, Michele; Poletti, Enrico; Popolo Rubbio, Antonio; Testa, Luca; Bedogni, Francesco; De Marco, Federico.
Afiliação
  • Casenghi M; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • Oliva OA; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • Squillace M; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • Bellamoli M; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • Poletti E; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • Popolo Rubbio A; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • Testa L; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • Bedogni F; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
  • De Marco F; Clinical and Interventional Cardiology Department, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico San Donato, Milan, Italy.
JACC Case Rep ; 3(4): 678-681, 2021 Apr.
Article em En | MEDLINE | ID: mdl-34317602
ABSTRACT
Redo transcatheter aortic valve replacement (TAVR) may pose the risk of coronary flow obstruction. We report 2 cases of severe TAVR regurgitation due to different physiopathological mechanisms in which TAVR-in-TAVR could be at high risk for sinus sequestration. Both cases were successfully treated by in-series implantation of a second transcatheter heart valve, thus avoiding sinus sequestration. (Level of Difficulty Intermediate.).
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: JACC Case Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: JACC Case Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália