Your browser doesn't support javascript.
loading
Comparison of allergen quantification strategies for egg, milk, and peanut in food using targeted LC-MS/MS.
Xiong, Weili; Parker, Christine H; Boo, Chelsea C; Fiedler, Katherine L.
Afiliação
  • Xiong W; U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, College Park, MD, 20740-3835, USA.
  • Parker CH; Joint Institute for Food Safety and Applied Nutrition, University of Maryland, College Park, MD, 20740, USA.
  • Boo CC; U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, College Park, MD, 20740-3835, USA.
  • Fiedler KL; U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, College Park, MD, 20740-3835, USA.
Anal Bioanal Chem ; 413(23): 5755-5766, 2021 Sep.
Article em En | MEDLINE | ID: mdl-34341840
Methods for the detection and quantification of food allergens in complex matrices are necessary to ensure compliance with labeling regulations and assess the effectiveness of food allergen preventive controls. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has emerged as an orthogonal technique in complement to immunochemical-based assays. However, the absence of established guidelines for MS-based quantification of allergens in food has limited harmonization among the method development community. In this study, different quantification strategies were evaluated using a previously developed multiplexed LC-MS/MS method for the detection of egg, milk, and peanut. Peptide performance criteria (retention time, signal-to-noise ratio, and ion ratio tolerance) were established and quantification approaches using varying calibrants, internal standards, background matrices, and calibration curve preparation schemes were systematically evaluated to refine the previous method for routine laboratory use. A matrix-matched calibration curve using allergen ingredients as calibrants and stable isotope-labeled peptides as internal standards provided the most accurate quantitative results. The strategy was further verified with commercially available reference materials and allowed for the confident detection and quantification of food allergens. This work highlights the need for transparency in calibration strategy and peptide performance requirements for effective evaluation of mass spectrometric methods for the quantification of food allergens.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arachis / Alérgenos / Cromatografia Líquida / Leite / Ovos / Espectrometria de Massas em Tandem / Hipersensibilidade Alimentar Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arachis / Alérgenos / Cromatografia Líquida / Leite / Ovos / Espectrometria de Massas em Tandem / Hipersensibilidade Alimentar Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos