Your browser doesn't support javascript.
loading
Adverse outcomes in vacuum-assisted delivery after detachment of non-metal cup: a retrospective cohort study.
Schreiber, Hanoch; Cohen, Gal; Farladansky-Gershnabel, Sivan; Shechter Maor, Gil; Sharon-Weiner, Maya; Biron-Shental, Tal.
Afiliação
  • Schreiber H; Department of Obstetrics and Gynecology, Meir Medical Center, 59 Tchernichovsky St., 44281, Kfar Saba, Israel. hanochsc@gmail.com.
  • Cohen G; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel. hanochsc@gmail.com.
  • Farladansky-Gershnabel S; Department of Obstetrics and Gynecology, Meir Medical Center, 59 Tchernichovsky St., 44281, Kfar Saba, Israel.
  • Shechter Maor G; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Sharon-Weiner M; Department of Obstetrics and Gynecology, Meir Medical Center, 59 Tchernichovsky St., 44281, Kfar Saba, Israel.
  • Biron-Shental T; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Arch Gynecol Obstet ; 305(2): 359-364, 2022 02.
Article em En | MEDLINE | ID: mdl-34365515
ABSTRACT

PURPOSE:

To evaluate neonatal and maternal outcomes associated with detachment of non-metal vacuum cup during delivery and to identify risk factors for these detachments.

METHODS:

This retrospective cohort study included women with singleton pregnancy, who underwent vacuum-assisted vaginal delivery with a non-metal vacuum cup in a single academic institution, January 2014-August 2019. Failed vacuum deliveries were excluded. Primary outcomes were defined as subgaleal hematoma (SGH) and cord blood pH < 7.15. Secondary outcome included other neonatal complications and adverse maternal outcomes. Outcomes were compared between vacuum-assisted deliveries with and without cup detachment during the procedure.

RESULTS:

A total of 3246 women had successful VAD and met the inclusion criteria. During the procedure, the cup detached at least once in 665 (20.5%) deliveries and did not detach in 2581 (79.5%). The cup detachment group experienced higher rates of SGH (8.9% vs. 3.5%, p = 0.001) and cord blood pH < 7.15 (9.8% vs. 7.1%, p = 0.03). There were also more neonatal intensive care unit admissions (NICU) (4.4% vs. 2.7%, p = 0.03) and more fetuses with occiput posterior position (70.8% vs. 79.4%, p = 0.001), the vacuum duration was slightly longer (6 ± 3.7 vs. 5 ± 2.9 min) and more neonates had birth weights > 3700 g (14.1% vs, 10.3%, p = 0.006). Interestingly, there were more males in that group (60.6 vs. 54.6, p = 0.005). All these factors remained significant after controlling for potential confounders.

CONCLUSIONS:

Vacuum cup detachment has several predictive characteristics and is associated with adverse neonatal outcomes that should be incorporated into decisions made during the procedure.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vácuo-Extração / Parto Obstétrico / Falha de Equipamento Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Newborn / Pregnancy Idioma: En Revista: Arch Gynecol Obstet Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Israel

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vácuo-Extração / Parto Obstétrico / Falha de Equipamento Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Newborn / Pregnancy Idioma: En Revista: Arch Gynecol Obstet Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Israel