A Rapid Prototyped Thermal Mass Flowmeter.
Sensors (Basel)
; 21(16)2021 Aug 09.
Article
em En
| MEDLINE
| ID: mdl-34450811
An innovative rapid prototyping technique for embedding microcomponents in PDMS replicas was developed and applied on a thermal mass flowmeter for closed loop micropump flowrate control. Crucial flowmeter design and thermal parameters were investigated with a 3-D fully coupled electro-thermal-fluidic model which was built in Comsol Multiphysics 5.2. The flowmeter was characterized for three distinct measuring configurations. For precise low flowrate applications, a sensor-heater-sensor flowmeter configuration with a constant heater temperature was found to be the most appropriate yielding the measuring range of 0 to 90 µL·min-1 and the sensitivity of 1.3 °C·µL-1·min in the lower flowrate range of 0 to 40 µL·min-1.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Fluxômetros
Idioma:
En
Revista:
Sensors (Basel)
Ano de publicação:
2021
Tipo de documento:
Article
País de afiliação:
Eslovênia