Your browser doesn't support javascript.
loading
Real-Time Fluorometric Isothermal LAMP Assay for Detection of Chlamydia pecorum in Rapidly Processed Ovine Abortion Samples: A Veterinary Practitioner's Perspective.
Clune, Tom; Anstey, Susan; Kasimov, Vasilli; Jacobson, Caroline; Jelocnik, Martina.
Afiliação
  • Clune T; Centre for Animal Production and Health, Murdoch University, South Street, Murdoch, Perth, WA 6150, Australia.
  • Anstey S; Genecology Research Centre, University of the Sunshine Coast, Sippy Downs, Sunshine Coast, QLD 4557, Australia.
  • Kasimov V; Genecology Research Centre, University of the Sunshine Coast, Sippy Downs, Sunshine Coast, QLD 4557, Australia.
  • Jacobson C; Centre for Animal Production and Health, Murdoch University, South Street, Murdoch, Perth, WA 6150, Australia.
  • Jelocnik M; Genecology Research Centre, University of the Sunshine Coast, Sippy Downs, Sunshine Coast, QLD 4557, Australia.
Pathogens ; 10(9)2021 Sep 08.
Article em En | MEDLINE | ID: mdl-34578188
Traditional methods of detecting Chlamydia pecorum in tissue samples such as polymerase chain reaction or cell culture are laborious and costly. We evaluated the use of a previously developed C. pecorum LAMP assay using minimally processed ovine samples. Cotyledon (n = 16), foetal liver (n = 22), foetal lung (n = 2), and vaginal (n = 6) swabs, in addition to cotyledon (n = 6) and foetal liver (n = 8) tissue samples, were rapidly processed and used for LAMP testing without DNA extraction. Overall, LAMP test results were highly congruent with the in-house reference qPCR, with 80.43% (37/46; 72.73% positive agreement (PA); 84.75% negative agreement (NA)) overall agreeance for swab samples, and 85.71% (12/14; 80% PA; 88.89% NA) overall agreeance for tissue samples. Out of the 11 total discrepant results, discrepancy was mainly observed in samples (n = 10) with less than 100 copies/µL C. pecorum DNA. While sensitivity could be improved, the simplicity, low cost, and accuracy of detection makes this test amenable for use at point-of-care for detecting C. pecorum in sheep.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Pathogens Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Pathogens Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Austrália