Your browser doesn't support javascript.
loading
Inline electrochemical reduction of NISTmAb for middle-up subunit liquid chromatography-mass spectrometry analysis.
Morgan, Tomos E; Jakes, Craig; Brouwer, Hendrik-Jan; Millán-Martín, Silvia; Chervet, Jean-Pierre; Cook, Ken; Carillo, Sara; Bones, Jonathan.
Afiliação
  • Morgan TE; Characterisation and Comparability Laboratory, NIBRT - the National Institute for bioprocessing research and training, Foster Avenue, Mount Merrion, Blackrock, Co., Dublin, A94 X099, Ireland. jonathan.bones@nibrt.ie.
  • Jakes C; Characterisation and Comparability Laboratory, NIBRT - the National Institute for bioprocessing research and training, Foster Avenue, Mount Merrion, Blackrock, Co., Dublin, A94 X099, Ireland. jonathan.bones@nibrt.ie.
  • Brouwer HJ; School of Chemical Engineering and Bioprocessing, University College of Dublin, Belfield, Dublin 4, Ireland.
  • Millán-Martín S; Antec Scientific, Industrieweg 12, 2382NV Zoeterwoude, The Netherlands.
  • Chervet JP; Characterisation and Comparability Laboratory, NIBRT - the National Institute for bioprocessing research and training, Foster Avenue, Mount Merrion, Blackrock, Co., Dublin, A94 X099, Ireland. jonathan.bones@nibrt.ie.
  • Cook K; Antec Scientific, Industrieweg 12, 2382NV Zoeterwoude, The Netherlands.
  • Carillo S; Thermo Fisher Scientific, Hemel Hempstead, Herts, HP2 7GE, UK.
  • Bones J; Characterisation and Comparability Laboratory, NIBRT - the National Institute for bioprocessing research and training, Foster Avenue, Mount Merrion, Blackrock, Co., Dublin, A94 X099, Ireland. jonathan.bones@nibrt.ie.
Analyst ; 146(21): 6547-6555, 2021 Oct 25.
Article em En | MEDLINE | ID: mdl-34585175
ABSTRACT
Disulfide bond reduction within antibody mass spectrometry workflows is typically carried out using chemical reducing agents to produce antibody subunits for middle-down and middle-up analysis. In this contribution we offer an online electrochemical reduction method for the reduction of antibodies coupled with liquid chromatography (LC) and mass spectrometry (MS), reducing the disulfide bonds present in the antibody without the need for chemical reducing agents. An electrochemical cell placed before the analytical column and mass spectrometer facilitated complete reduction of NISTmAb inter- and intrachain disulfide bonds. Reduction and analysis were carried out under optimal solvent conditions using a trapping column and switching valve to facilitate solvent exchange during analysis. The level of reduction was shown to be affected by electrochemical potential, temperature and solvent organic content, but with optimization, complete disulfide bond cleavage was achieved. The use of an inline electrochemical cell offers a simple, rapid, workflow solution for liquid chromatography mass spectrometry analysis of antibody subunits.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dissulfetos / Técnicas Eletroquímicas Idioma: En Revista: Analyst Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Irlanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dissulfetos / Técnicas Eletroquímicas Idioma: En Revista: Analyst Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Irlanda