A multiplexed, automated immuno-matrix assisted laser desorption/ionization mass spectrometry assay for simultaneous and precise quantitation of PTEN and p110α in cell lines and tumor tissues.
Froehlich, Bjoern C; Popp, Robert; Sobsey, Constance A; Ibrahim, Sahar; LeBlanc, Andre; Mohammed, Yassene; Buchanan, Marguerite; Aguilar-Mahecha, Adriana; Pötz, Oliver; Chen, Michael X; Spatz, Alan; Basik, Mark; Batist, Gerald; Zahedi, René P; Borchers, Christoph H.
Afiliação
  • Froehlich BC; University of Victoria - Genome BC Proteomics Centre, University of Victoria, Victoria, British Columbia V8Z 7X8, Canada.
  • Popp R; Department of Biochemistry and Microbiology, University of Victoria, Victoria, British Columbia V8P 5C2, Canada.
  • Sobsey CA; University of Victoria - Genome BC Proteomics Centre, University of Victoria, Victoria, British Columbia V8Z 7X8, Canada.
  • Ibrahim S; Segal Cancer Proteomics Centre, Lady Davis Institute, Jewish General Hospital, McGill University, Montreal, QC H3T1E2, Canada.
  • LeBlanc A; Segal Cancer Proteomics Centre, Lady Davis Institute, Jewish General Hospital, McGill University, Montreal, QC H3T1E2, Canada.
  • Mohammed Y; Segal Cancer Proteomics Centre, Lady Davis Institute, Jewish General Hospital, McGill University, Montreal, QC H3T1E2, Canada.
  • Buchanan M; University of Victoria - Genome BC Proteomics Centre, University of Victoria, Victoria, British Columbia V8Z 7X8, Canada.
  • Aguilar-Mahecha A; Center for Proteomics and Metabolomics, Leiden University Medical Center, Leiden, The Netherlands.
  • Pötz O; Center for Computational and Data-Intensive Science and Engineering, Skolkovo Institute of Science and Technology, Moscow 121205, Russia.
  • Chen MX; Segal Cancer Centre, Lady Davis Institute, Jewish General Hospital, McGill University, Montreal, QC H3T1E2, Canada.
  • Spatz A; Segal Cancer Centre, Lady Davis Institute, Jewish General Hospital, McGill University, Montreal, QC H3T1E2, Canada.
  • Basik M; NMI Natural and Medical Sciences Institute at the University of Tuebingen, Reutlingen 72770, Germany.
  • Batist G; SIGNATOPE GmbH, Reutlingen 72770, Germany.
  • Zahedi RP; Department of Pathology and Laboratory Medicine, Faculty of Medicine, University of British Columbia, Vancouver, Canada.
  • Borchers CH; Segal Cancer Centre, Lady Davis Institute, Jewish General Hospital, McGill University, Montreal, QC H3T1E2, Canada.
Analyst ; 146(21): 6566-6575, 2021 Oct 25.
Article em En | MEDLINE | ID: mdl-34585690
ABSTRACT
The PI3-kinase/AKT/mTOR pathway plays a central role in cancer signaling. While p110α is the catalytic α-subunit of PI3-kinase and a major drug target, PTEN is the main negative regulator of the PI3-kinase/AKT/mTOR pathway. PTEN is often down-regulated in cancer, and there are conflicting data on PTEN's role as breast cancer biomarker. PTEN and p110α protein expression in tumors is commonly analyzed by immunohistochemistry, which suffers from poor multiplexing capacity, poor standardization, and antibody crossreactivity, and which provides only semi-quantitative data. Here, we present an automated, and standardized immuno-matrix-assisted laser desorption/ionization mass spectrometry (iMALDI) assay that allows precise and multiplexed quantitation of PTEN and p110α concentrations, without the limitations of immunohistochemistry. Our iMALDI assay only requires a low-cost benchtop MALDI-TOF mass spectrometer, which simplifies clinical translation. We validated our assay's precision and accuracy, with simultaneous enrichment of both target proteins not significantly affecting the precision and accuracy of the quantitation when compared to the PTEN- and p110α-singleplex iMALDI assays (<15% difference). The multiplexed assay's linear range is from 0.6-20 fmol with accuracies of 90-112% for both target proteins, and the assay is free of matrix-related interferences. The inter-day reproducibility over 5-days was high, with an overall CV of 9%. PTEN and p110α protein concentrations can be quantified down to 1.4 fmol and 0.6 fmol per 10 µg of total tumor protein, respectively, in various tumor tissue samples, including fresh-frozen breast tumors and colorectal cancer liver metastases, and patient-derived xenograft (PDX) tumors.