Multi-angle pulse shape detection of scattered light in flow cytometry for label-free cell cycle classification.
Kage, Daniel; Heinrich, Kerstin; Volkmann, Konrad V; Kirsch, Jenny; Feher, Kristen; Giesecke-Thiel, Claudia; Kaiser, Toralf.
Afiliação
  • Kage D; German Rheumatism Research Centre Berlin (DRFZ)-Flow Cytometry Core Facility, Charitéplatz 1 (Virchowweg 12), 10117, Berlin, Germany.
  • Heinrich K; German Rheumatism Research Centre Berlin (DRFZ)-Flow Cytometry Core Facility, Charitéplatz 1 (Virchowweg 12), 10117, Berlin, Germany.
  • Volkmann KV; APE Angewandte Physik und Elektronik GmbH, Plauener Straße 163-165 / Haus N, 13053, Berlin, Germany.
  • Kirsch J; German Rheumatism Research Centre Berlin (DRFZ)-Flow Cytometry Core Facility, Charitéplatz 1 (Virchowweg 12), 10117, Berlin, Germany.
  • Feher K; EMBL Australia Node in Single Molecule Science, School of Medical Sciences, University of New South Wales, Sydney, Australia.
  • Giesecke-Thiel C; Flow Cytometry Facility, Max Planck Institute for Molecular Genetics, Ihnestraße 63-73, 14195, Berlin, Germany. giesecke@molgen.mpg.de.
  • Kaiser T; German Rheumatism Research Centre Berlin (DRFZ)-Cell Biology, Berlin, Germany. giesecke@molgen.mpg.de.
Commun Biol ; 4(1): 1144, 2021 09 30.
Article em En | MEDLINE | ID: mdl-34593965
ABSTRACT
Flow cytometers are robust and ubiquitous tools of biomedical research, as they enable high-throughput fluorescence-based multi-parametric analysis and sorting of single cells. However, analysis is often constrained by the availability of detection reagents or functional changes of cells caused by fluorescent staining. Here, we introduce MAPS-FC (multi-angle pulse shape flow cytometry), an approach that measures angle- and time-resolved scattered light for high-throughput cell characterization to circumvent the constraints of conventional flow cytometry. In order to derive cell-specific properties from the acquired pulse shapes, we developed a data analysis procedure based on wavelet transform and k-means clustering. We analyzed cell cycle stages of Jurkat and HEK293 cells by MAPS-FC and were able to assign cells to the G1, S, and G2/M phases without the need for fluorescent labeling. The results were validated by DNA staining and by sorting and re-analysis of isolated G1, S, and G2/M populations. Our results demonstrate that MAPS-FC can be used to determine cell properties that are otherwise only accessible by invasive labeling. This approach is technically compatible with conventional flow cytometers and paves the way for label-free cell sorting.