Noncontact characterization of microstructured optical fibers coating in real time.
Opt Lett
; 46(19): 4793-4796, 2021 Oct 01.
Article
em En
| MEDLINE
| ID: mdl-34598201
Functional nanocoatings have allowed hollow-core microstructured optical fibers (HC-MOFs) to be introduced into biosensing and photochemistry applications. However, common film characterization tools cannot evaluate the coating performance in situ. Here we report the all-optical noncontact characterization of the HC-MOF coating in real time. Self-assembled multilayers consisting of inversely charged polyelectrolytes (PEs) are deposited on the HC-MOF core capillary, and a linear spectral shift in the position of the fiber transmission minima with increasing the film thickness is observed as small as â¼1.5-6nm per single PE bilayer. We exemplify the practical performance of our approach by registering an increase in the coating thickness from 6±1 to 11±1nm per PE bilayer with increasing ionic strength in the PE solutions from 0.15 to 0.5 M NaCl. Additionally, we show real-time monitoring of pH-induced coating dissolving. Simplicity and high sensitivity make our approach a promising tool allowing noncontact analysis of the HC-MOF coating which is still challenging for other methods.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Fibras Ópticas
Idioma:
En
Revista:
Opt Lett
Ano de publicação:
2021
Tipo de documento:
Article