Your browser doesn't support javascript.
loading
Improving LC-MS analysis of human milk B-vitamins by lactose removal.
Hampel, Daniela; Shahab-Ferdows, Setareh; Newman, John W; Allen, Lindsay H.
Afiliação
  • Hampel D; USDA, ARS Western Human Nutrition Research Center, 430 West Health Sciences Drive, Davis, CA 95616, USA; Department of Nutrition, University of California, One Shields Ave, Davis, CA 95616, USA. Electronic address: dhampel@ucdavis.edu.
  • Shahab-Ferdows S; USDA, ARS Western Human Nutrition Research Center, 430 West Health Sciences Drive, Davis, CA 95616, USA.
  • Newman JW; USDA, ARS Western Human Nutrition Research Center, 430 West Health Sciences Drive, Davis, CA 95616, USA; Department of Nutrition, University of California, One Shields Ave, Davis, CA 95616, USA.
  • Allen LH; USDA, ARS Western Human Nutrition Research Center, 430 West Health Sciences Drive, Davis, CA 95616, USA; Department of Nutrition, University of California, One Shields Ave, Davis, CA 95616, USA.
Article em En | MEDLINE | ID: mdl-34628184
ABSTRACT
Our previously reported, first validated, UPLC-MS/MS-based simultaneous analysis of five human milk B-vitamins revealed severe matrix effects. High levels of endogenous lactose fouled the electrospray ionization source affecting the analysis. We evaluated solid-phase extraction (SPE), liquid-solid extraction (LSE), protein precipitation (PPT), and liquid chromatography effluent diversion for lactose-removal. SPE failed to separate lactose from vitamins; LSE using 2-propanol reduced lactose and vitamin recoveries. PPT-solvent, milk volume, and reconstitution solvent influenced flavin adenine dinucleotide, pyridoxal and nicotinamide recoveries. Using an optimized LC-gradient enabled chromatographic separation of lactose from vitamins and its removal using a post-column switch-valve. Only 40 µL milk was subjected to methanol-PPT and non-polar matrix removal by methyl tert-butyl ether. B-vitamin recoveries were established (81.9-118.6%; CV ≤ 11.9%; precision 4.9-13.7%) with greatly reduced matrix effects, and improved process efficiency, and recovery.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complexo Vitamínico B / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Lactose / Leite Humano Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complexo Vitamínico B / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Lactose / Leite Humano Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2021 Tipo de documento: Article