Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses.
Wang, Fuyixue; Dong, Zijing; Wald, Lawrence L; Polimeni, Jonathan R; Setsompop, Kawin.
Afiliação
  • Wang F; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. Electronic address: fwang18@mgh.harvard.edu.
  • Dong Z; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Electrical Engineering and Computer Science, MIT, Cambridge, MA, USA.
  • Wald LL; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA.
  • Polimeni JR; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA.
  • Setsompop K; Department of Radiology, Stanford University, Stanford, USA; Department of Electrical Engineering, Stanford University, Stanford, USA.
Neuroimage ; 245: 118641, 2021 12 15.
Article em En | MEDLINE | ID: mdl-34655771
Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T2' contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T2' contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T2' weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T2'-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B0 drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T2' weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mapeamento Encefálico / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mapeamento Encefálico / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article