Your browser doesn't support javascript.
loading
Long-term evaluation of an air-cathode microbial fuel cell with an anion exchange membrane in a 226L wastewater treatment reactor.
Sugioka, Mari; Yoshida, Naoko; Yamane, Taiki; Kakihana, Yuriko; Higa, Mitsuru; Matsumura, Takahiro; Sakoda, Mitsuhiro; Iida, Kazuki.
Afiliação
  • Sugioka M; Department of Civil and Environmental Engineering, Nagoya Institute of Technology (Nitech), Gokiso-Cho, Showa-Ku, Nagoya, Aichi, Japan.
  • Yoshida N; Department of Civil and Environmental Engineering, Nagoya Institute of Technology (Nitech), Gokiso-Cho, Showa-Ku, Nagoya, Aichi, Japan. Electronic address: yoshida.naoko@nitech.ac.jp.
  • Yamane T; Department of Civil and Environmental Engineering, Nagoya Institute of Technology (Nitech), Gokiso-Cho, Showa-Ku, Nagoya, Aichi, Japan.
  • Kakihana Y; Graduate School of Sciences and Technology for Innovation, Yamaguchi University, Japan.
  • Higa M; Graduate School of Sciences and Technology for Innovation, Yamaguchi University, Japan.
  • Matsumura T; Research Center, TOYOBO Co., LTD., 2-1-1, Katata, Otsu, Shiga, Japan.
  • Sakoda M; Water & Sewage Department, Tamano Consultants Co., Ltd., 2-17-14, Higashisakura, Higashi-ku, Nagoya, Aichi, Japan.
  • Iida K; River & Water Resources Division, NIPPON KOEI Co., Ltd., 5-4 Kojimachi, Chiyoda-ku, Tokyo, Japan.
Environ Res ; 205: 112416, 2022 04 01.
Article em En | MEDLINE | ID: mdl-34808126
Although the treatment of municipal wastewater using microbial fuel cells (MFCs) has been extensively studied, scaling the systems up for practical use remains challenging. In this study, a 226 L sewage treatment reactor was equipped with 27 MFC units, and its chemical oxygen demand (COD) removal and electricity production were evaluated. The MFC units were tubular air cores with a diameter of 5 cm and length of 100 cm, which were wrapped with a carbon-based cathode, anion exchange membrane (AEM), and nonwoven graphite fabric. The air-cathode-AEM MFC generated 0.12-0.30 A/m2, 0.072-0.51 W/m3, and 1.7-4.6 Wh/m3 in a chemostat reactor with a COD of 140-36 mg/L and hydraulic retention time (HRT) of 9-42 h throughout a year. The decrease in the COD was represented as the first-order rate constant of 0.038. The rate constant was comparable to that of other air-cathode MFCs with cation exchange membranes, indicating the necessity of a posttreatment to meet the discharge standard. It has been estimated that the MFC operation for 24 h before post-aeration can reduce the energy required to meet the discharge standard by 70%, suggesting the potential applicability of MFC in long HRT-treatments such as oxidation ditch. The resistances of the anode, cathode, and AEM were 15, 7.0, and 0.51 mΩ m2, respectively, and surface dirt rather than deterioration primarily increased the AEM resistance. A current exceeding 0.2 A/m2 significantly increases the anode potential, indicating that the current was limited by low COD. Increasing the anode-specific surface area can improve air-AEM MFCs used for practical applications.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fontes de Energia Bioelétrica / Purificação da Água Idioma: En Revista: Environ Res Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fontes de Energia Bioelétrica / Purificação da Água Idioma: En Revista: Environ Res Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão