The carbon footprint of cataract surgery in a French University Hospital.
Ferrero, A; Thouvenin, R; Hoogewoud, F; Marcireau, I; Offret, O; Louison, P; Monnet, D; Brézin, A P.
Afiliação
  • Ferrero A; Université de Paris, Hôpital Cochin, Service d'ophtalmologie, Paris, France.
  • Thouvenin R; Université de Paris, Hôpital Cochin, Service d'ophtalmologie, Paris, France.
  • Hoogewoud F; Université de Paris, Hôpital Cochin, Service d'ophtalmologie, Paris, France.
  • Marcireau I; Université de Paris, Hôpital Cochin, Service d'ophtalmologie, Paris, France.
  • Offret O; Université de Paris, Hôpital Cochin, Service d'ophtalmologie, Paris, France.
  • Louison P; Hôpital Cochin, service d'ingénierie, 27, rue du Faubourg-Saint-Jacques, 75014 Paris, France.
  • Monnet D; Université de Paris, Hôpital Cochin, Service d'ophtalmologie, Paris, France.
  • Brézin AP; Université de Paris, Hôpital Cochin, Service d'ophtalmologie, Paris, France. Electronic address: antoine.brezin@aphp.fr.
J Fr Ophtalmol ; 45(1): 57-64, 2022 Jan.
Article em En | MEDLINE | ID: mdl-34823888
PURPOSE: To assess the carbon footprint of cataract surgery in a French university hospital. SETTING: Operating room of Cochin University Hospital, Paris, France. DESIGN: Single-center component analysis. METHODS: One day of surgery was used as a reference. Greenhouse gases (GHG) related to patient and staff transportation were calculated based on the distance travelled and the means of transportation used. The annual consumption of energy (heating and electricity) of our building was converted in kg equivalent of carbon dioxide (CO2eq), and the principle of proportionality was used to calculate what was used for a single cataract procedure. GHG emissions related to the life cycle assessment (LCA) of the equipment used and the sterilization process were calculated. RESULTS: The LCA of disposable items accounted for 59.49kg (73.32%) of CO2eq for each procedure. A single procedure generated 2.83±0.10kg of waste. The average CO2eq produced by the transportation of the patients to and from our center, adjusted for one procedure, was 7.26±6.90kg (8.95%) of CO2eq. The CO2eq produced by the sterilization of the phacoemulsifier handpiece was 2.12kg (2.61%). The energy consumption of the building and staff transportation accounted for the remaining CO2eq emissions, 0.76kg (0.93%) and 0.08kg (0.10%) respectively. Altogether, the carbon footprint of one cataract procedure in our center was 81.13kg CO2eq - the equivalent of an average car driving 800km. CONCLUSION: Our data provide a basis to quantify cataract surgery as a source of GHG and suggests that reductions in emissions can be achieved.