Your browser doesn't support javascript.
loading
Impedance planimetry (EndoFLIP™) reveals changes in gastroesophageal junction compliance during fundoplication.
Wu, Hoover; Attaar, Mikhail; Wong, Harry J; Campbell, Michelle; Kuchta, Kristine; Denham, Woody; Linn, John; Ujiki, Michael B.
Afiliação
  • Wu H; Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA. hoover.wu@uchospitals.edu.
  • Attaar M; Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA. hoover.wu@uchospitals.edu.
  • Wong HJ; Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA.
  • Campbell M; Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA.
  • Kuchta K; Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA.
  • Denham W; Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA.
  • Linn J; Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA.
  • Ujiki MB; Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA.
Surg Endosc ; 36(9): 6801-6808, 2022 09.
Article em En | MEDLINE | ID: mdl-35015103
ABSTRACT

INTRODUCTION:

Compliance is the ability of a hollow organ to dilate and increase volume with an increase in pressure, an accurate representation of food bolus transit through the gastroesophageal junction (GEJ). Impedance planimetry system can calculate compliance (change in volume over pressure) and distensibility (cross-sectional area over pressure) of the GEJ. We aim to describe the changes in compliance during anti-reflux surgery and hypothesize that compliance is a better predictor of patient outcomes than distensibility (DI). METHODS AND PROCEDURES A review of a prospectively maintained quality database was performed. Patients with FLIP measurements during laparoscopic fundoplication between August 2018 and June 2021 were included. GEJ compliance and DI were measured after hernia reduction, cruroplasty, and fundoplication. Patient-reported outcomes were collected through standardized surveys up to 2 years after surgery. A scatter plot was used to identify a correlation between compliance and DI. Comparisons of measurements between time points were made using paired t-tests. Spearman's correlation coefficients (ρ), Wilcoxon rank-sum, and chi-square tests were used to evaluate associations between measurements and outcomes.

RESULTS:

One hundred and forty-four patients underwent laparoscopic fundoplication. Compliance is strongly associated with DI (r = 0.96), and a comparison of measurements showed similar trends at specific time points during the operation. After hernia reduction, compliance at the GEJ was 168 ± 74 mm3/mmHg, cruroplasty 79 ± 39 mm3/mmHg, and fundoplication 90 ± 33 mm3/mmHg (all comparisons p < 0.05). GEJ compliance of 80-92 mm3/mmHg after fundoplication was associated with the best patient-reported outcome scores. A compliance of ≤ 79 mm3/mmHg had the highest percentage of patients who reported dysphagia.

CONCLUSIONS:

Compliance and DI are strongly associated displaying the same directional change during anti-reflux surgery. GEJ compliance of 80-92 mm3/mmHg revealed the best patient-reported outcome scores, and avoiding a compliance ≤ 79 mm3/mmHg may prevent postoperative dysphagia. Therefore, GEJ compliance is an underutilized FLIP measurement warranting further investigation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transtornos de Deglutição / Refluxo Gastroesofágico / Laparoscopia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transtornos de Deglutição / Refluxo Gastroesofágico / Laparoscopia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos