Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes.
Garg, Satish K; Kipnes, Mark; Castorino, Kristin; Bailey, Timothy S; Akturk, Halis Kaan; Welsh, John B; Christiansen, Mark P; Balo, Andrew K; Brown, Sue A; Reid, Jennifer L; Beck, Stayce E.
Afiliação
  • Garg SK; Department of Medicine and Pediatrics, Barbara Davis Center for Diabetes, University of Colorado, Aurora, Colorado, USA.
  • Kipnes M; DGD Clinic, San Antonio, Texas, USA.
  • Castorino K; Sansum Diabetes Research Institute, Santa Barbara, California, USA.
  • Bailey TS; AMCR Institute, Escondido, California, USA.
  • Akturk HK; Department of Medicine and Pediatrics, Barbara Davis Center for Diabetes, University of Colorado, Aurora, Colorado, USA.
  • Welsh JB; Dexcom, Inc., San Diego, California, USA.
  • Christiansen MP; Diablo Clinical Research, Walnut Creek, California, USA.
  • Balo AK; Dexcom, Inc., San Diego, California, USA.
  • Brown SA; University of Virginia, Charlottesville, Virginia, USA.
  • Reid JL; Dexcom, Inc., San Diego, California, USA.
  • Beck SE; Dexcom, Inc., San Diego, California, USA.
Diabetes Technol Ther ; 24(6): 373-380, 2022 06.
Article em En | MEDLINE | ID: mdl-35157505
Background: We evaluated the accuracy and safety of a seventh generation (G7) Dexcom continuous glucose monitor (CGM) during 10.5 days of use in adults with diabetes. Methods: Adults with either type 1 or type 2 diabetes (on intensive insulin therapy or not) participated at 12 investigational sites in the United States. In-clinic visits were conducted on days 1 or 2, 4 or 7, and on the second half of day 10 or the first half of day 11 for frequent comparisons with comparator blood glucose measurements obtained with the YSI 2300 Stat Plus glucose analyzer. Participants wore sensors concurrently on the upper arm and abdomen. Accuracy evaluation included the proportion of CGM values within 15% of comparator glucose levels >100 mg/dL or within 15 mg/dL of comparator levels ≤100 mg/dL (%15/15), along with the %20/20 and %30/30 agreement rates. The mean absolute relative difference (MARD) between temporally matched CGM and comparator values was also calculated. Results: Data from 316 participants (619 sensors, 77,774 matched pairs) were analyzed. For arm- and abdomen-placed sensors, overall MARDs were 8.2% and 9.1%, respectively. Overall %15/15, %20/20, and %30/30 agreement rates were 89.6%, 95.3%, and 98.8% for arm-placed sensors and were 85.5%, 93.2%, and 98.1% for abdomen-placed sensors. Across days of wear, glucose concentration ranges, and rates of change, %20/20 agreement rates varied by no more than 9% from the overall %20/20. No serious adverse events were reported. Conclusions: The G7 CGM provides accurate glucose readings with single-digit MARD with arm or abdomen placement in adults with diabetes. Clinicaltrials.gov: NCT04794478.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 Limite: Adult / Humans Idioma: En Revista: Diabetes Technol Ther Assunto da revista: ENDOCRINOLOGIA / TERAPEUTICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 Limite: Adult / Humans Idioma: En Revista: Diabetes Technol Ther Assunto da revista: ENDOCRINOLOGIA / TERAPEUTICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos