Your browser doesn't support javascript.
loading
Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?
Kim, Beom-Soo; Kim, Du-Han; Choi, Jung-Hoon; Choi, Byung-Chan; Cho, Chul-Hyun.
Afiliação
  • Kim BS; Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Korea.
  • Kim DH; Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Korea.
  • Choi JH; Department of Orthopedic Surgery, Bogang Hospital, 102 Wolbae-ro, Dalseo-gu, Daegu 42801, Korea.
  • Choi BC; Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Korea.
  • Cho CH; Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Korea.
Medicina (Kaunas) ; 58(3)2022 Mar 04.
Article em En | MEDLINE | ID: mdl-35334558
ABSTRACT
Background and

Objectives:

The aim of this study was to evaluate whether device removal in symptomatic patients following locking plate osteosynthesis of a proximal humerus fracture improves the clinical outcomes. Materials and

Methods:

Seventy-one patients who underwent fixed-angle locking plate osteosynthesis of a proximal humerus fracture were included. Thirty-three patients underwent device removal at a mean time of 10.4 months after index surgery (removal group). Thirty-eight patients who retained the device after index surgery (retention group) were included in the control group. Visual analog scale (VAS) pain score, University of California at Los Angeles (UCLA) score, American Shoulder and Elbow Surgeons (ASES) score, and range of motion (ROM) were evaluated pre- and postoperatively.

Results:

At the final follow-up, mean UCLA score, ASES score, and all ROMs were significantly higher in the removal group compared to the retention group (p < 0.001). However, no significant difference in mean VAS pain score was observed between the two groups. Comparison of the clinical outcomes before and after device removal surgery showed significant improvement in all clinical scores and ROMs after device removal (p < 0.001).

Conclusions:

Device removal surgery in symptomatic patients following locking plate osteosynthesis of a proximal humerus fracture can result in significant improvement in functional outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Ombro / Remoção de Dispositivo Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Medicina (Kaunas) Assunto da revista: MEDICINA Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Ombro / Remoção de Dispositivo Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Medicina (Kaunas) Assunto da revista: MEDICINA Ano de publicação: 2022 Tipo de documento: Article