Your browser doesn't support javascript.
loading
Evaluation of the clinical application effect of eSource record tools for clinical research.
Wang, Bin; Hao, Xinbao; Yan, Xiaoyan; Lai, Junkai; Jin, Feifei; Liao, Xiwen; Xie, Hongju; Yao, Chen.
Afiliação
  • Wang B; Peking University Clinical Research Institute, Peking University First Hospital, Beijing, China.
  • Hao X; Department of Hematology, First Affiliated Hospital of Hainan Medical College, Haikou, China.
  • Yan X; Boao Lecheng Tigermed Clinical Research Center, Qionghai, China.
  • Lai J; Peking University Clinical Research Institute, Peking University First Hospital, Beijing, China.
  • Jin F; Peking University Clinical Research Institute, Peking University First Hospital, Beijing, China.
  • Liao X; National Center for Trauma Medicine, Peking University People's Hospital, Beijing, China.
  • Xie H; Peking University Clinical Research Institute, Peking University First Hospital, Beijing, China.
  • Yao C; Department of Plastic and Cosmetic Surgery, The Second Affiliated Hospital of Hainan Medical University, Haikou, China.
BMC Med Inform Decis Mak ; 22(1): 98, 2022 04 11.
Article em En | MEDLINE | ID: mdl-35410214
BACKGROUND: Electronic sources (eSources) can improve data quality and reduce clinical trial costs. Our team has developed an innovative eSource record (ESR) system in China. This study aims to evaluate the efficiency, quality, and system performance of the ESR system in data collection and data transcription. METHODS: The study used time efficiency and data transcription accuracy indicators to compare the eSource and non-eSource data collection workflows in a real-world study (RWS). The two processes are traditional data collection and manual transcription (the non-eSource method) and the ESR-based source data collection and electronic transmission (the eSource method). Through the system usability scale (SUS) and other characteristic evaluation scales (system security, system compatibility, record quality), the participants' experience of using ESR was evaluated. RESULTS: In terms of the source data collection (the total time required for writing electronic medical records (EMRs)), the ESR system can reduce the time required by 39% on average compared to the EMR system. In terms of data transcription (electronic case report form (eCRF) filling and verification), the ESR can reduce the time required by 80% compared to the non-eSource method (difference: 223 ± 21 s). The ESR accuracy in filling the eCRF field is 96.92%. The SUS score of ESR is 66.9 ± 16.7, which is at the D level and thus very close to the acceptable margin, indicating that optimization work is needed. CONCLUSIONS: This preliminary evaluation shows that in the clinical medical environment, the ESR-based eSource method can improve the efficiency of source data collection and reduce the workload required to complete data transcription.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Registros Eletrônicos de Saúde / Confiabilidade dos Dados Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: BMC Med Inform Decis Mak Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Registros Eletrônicos de Saúde / Confiabilidade dos Dados Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: BMC Med Inform Decis Mak Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China