Your browser doesn't support javascript.
loading
Fluorescence quenching mediated detection of hydrogen peroxide using tungsten incorporated graphitic carbon nitride nanoflakes.
Ahmed, Aftab; Hayat, Akhtar; Nawaz, Mian Hasnain; Chaudhry, Aqif Anwar; John, Peter; Nasir, Muhammad.
Afiliação
  • Ahmed A; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus 1.5 km Defence Road, Off Raiwind Road Lahore Punjab 54000 Pakistan muhammadnasir@cuilahore.edu.pk +92-42-5321090 +92-42-111-001-007 ext. 828, 829.
  • Hayat A; Government College University Lahore Katchery Road, Anarkali Lahore Punjab 54000 Pakistan peterjohn@gcu.edu.pk.
  • Nawaz MH; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus 1.5 km Defence Road, Off Raiwind Road Lahore Punjab 54000 Pakistan muhammadnasir@cuilahore.edu.pk +92-42-5321090 +92-42-111-001-007 ext. 828, 829.
  • Chaudhry AA; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus 1.5 km Defence Road, Off Raiwind Road Lahore Punjab 54000 Pakistan muhammadnasir@cuilahore.edu.pk +92-42-5321090 +92-42-111-001-007 ext. 828, 829.
  • John P; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus 1.5 km Defence Road, Off Raiwind Road Lahore Punjab 54000 Pakistan muhammadnasir@cuilahore.edu.pk +92-42-5321090 +92-42-111-001-007 ext. 828, 829.
  • Nasir M; Government College University Lahore Katchery Road, Anarkali Lahore Punjab 54000 Pakistan peterjohn@gcu.edu.pk.
RSC Adv ; 11(13): 7479-7491, 2021 Feb 10.
Article em En | MEDLINE | ID: mdl-35423270
ABSTRACT
A reliable, non-enzymatic detection for H2O2 with high sensitivity and accuracy is of profound importance and getting considerable interest due to its usefulness in biological systems. Therefore, this work was aimed to develop a sensitive method for the detection of H2O2 using rhodamine B as a fluorescence system and tungsten doped graphitic carbon nitride (W/GCN) as catalysts. Fluorescence quenching and colorimetric properties of the chromogenic-dye probe were used as a detection strategy of H2O2. The enhanced catalytic property of nanoflakes of W/GCN was attributed to the unique structural characteristics, influenced by the dopant, that not only tuned its bandgap but also enhanced separation of electron-hole pairs as compared to planar and larger sized nanosheets of pristine GCN. This low-cost and rapid assay offered a very low limit of detection of 8 nM for the fluorescence quenching method and 20 nM for the colorimetric method. The linear range for fluorescence quenching and colorimetric H2O2 assays were from 10-500 nM and 35-400 nM, respectively. Therefore, this novel method of using W/GCN nanoflakes in fluorescence quenching and colorimetric based detections of H2O2 is expected to catch more interest on the topic of using non-enzymatic platforms for sensitive and selective detection of different analysts.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: RSC Adv Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: RSC Adv Ano de publicação: 2021 Tipo de documento: Article