Your browser doesn't support javascript.
loading
High-Precision Log-Ratio Spot Position Detection Algorithm with a Quadrant Detector under Different SNR Environments.
Huo, Li; Wu, Zhiyong; Wu, Jiabin; Gao, Shijie; Chen, Yunshan; Song, Yinuo; Wang, Shuaifei.
Afiliação
  • Huo L; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Wu Z; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Wu J; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Gao S; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Chen Y; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Song Y; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Wang S; University of Chinese Academy of Sciences, Beijing 100049, China.
Sensors (Basel) ; 22(8)2022 Apr 18.
Article em En | MEDLINE | ID: mdl-35459076
ABSTRACT
In atmospheric laser communication, a beam is transmitted through an atmospheric channel, and the photocurrent output from a quadrant detector (QD) used as the tracking sensor fluctuates significantly. To ensure uninterrupted communication and to adapt to such fluctuations, in this paper we apply logarithmic amplifiers to process the output signals of a QD. To further improve the measurement accuracy of the spot position, we firstly propose an integral infinite log-ratio algorithm (IILRA) and an integral infinity log-ratio algorithm based on the signal-to-noise ratio (BSNR-IILRA) through analysis of the factors influencing the measurement error considering the signal-to-noise ratio (SNR) parameter. Secondly, the measurement error of the two algorithms under different SNRs and their variations are analyzed. Finally, a spot position detection experiment platform is built to correctly and efficiently verify the two algorithms. The experimental results show that when the SNR is 54.10 dB, the maximum error and root mean square error of the spot position of the IILRA are 0.0054 mm and 0.0039 mm, respectively, which are less than half those of the center approximation algorithm (CAA). When the SNR is 23.88 dB, the maximum error and root mean square error of the spot position of the BSNR-IILRA are 0.0046 mm and 0.0034 mm, respectively, which are one-thirtieth and one-twentieth of the CAA, respectively. The spot position measurement accuracy of the two proposed algorithms is significantly improved compared with the CAA.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China