Your browser doesn't support javascript.
loading
Gradient-echo-train-based sub-millisecond periodic event encoded dynamic imaging with random (k, t)-space undersampling: k-t get-SPEEDI.
Luo, Qingfei; Zhong, Zheng; Sun, Kaibao; Scotti, Alessandro; Zhou, Xiaohong Joe.
Afiliação
  • Luo Q; Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Zhong Z; Department of Radiology, Stanford University, Stanford, California, USA.
  • Sun K; Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Scotti A; Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Zhou XJ; Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.
Magn Reson Med ; 88(4): 1690-1701, 2022 10.
Article em En | MEDLINE | ID: mdl-35666824
PURPOSE: The gradient-echo-train-based Sub-millisecond Periodic Event Encoded Dynamic Imaging (get-SPEEDI) technique provides ultrahigh temporal resolutions (∼0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at developing a more efficient variant of get-SPEEDI for reducing the scan time without degrading temporal resolution or image quality. METHODS: The proposed pulse sequence, named k-t get-SPEEDI, accelerated get-SPEEDI acquisition by undersampling the k-space phase-encoding lines semi-randomly. At each time frame, k-space was fully sampled in the central region whereas randomly undersampled in the outer regions. A time-series of images was reconstructed using an algorithm based on the joint partial separability and sparsity constraints. To demonstrate the performance of k-t get-SPEEDI, images of human aortic valve opening and closing were acquired with 0.6-ms temporal resolution and compared with those from conventional get-SPEEDI. RESULTS: k-t get-SPEEDI achieved a 2-fold scan time reduction over the conventional get-SPEEDI (from ∼6 to ∼3 min), while achieving comparable SNRs and contrast-to-noise ratio (CNRs) for visualizing the dynamic process of aortic valve: SNR/CNR ≈$$ \approx $$ 70/38 vs. 73/39 in the k-t and conventional get-SPEEDI scans, respectively. The time courses of aortic valve area also matched well between these two sequences with a correlation coefficient of 0.86. CONCLUSIONS: The k-t get-SPEEDI pulse sequence was able to half the scan time without compromising the image quality and ultrahigh temporal resolution. Additional scan time reduction may also be possible, facilitating in vivo adoptions of SPEEDI techniques.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos