Detecting Early-Stage Liver Fibrosis Using Macromolecular Proton Fraction Mapping Based on Spin-Lock MRI: Preliminary Observations.
Hou, Jian; Wong, Vincent W-S; Qian, Yurui; Jiang, Baiyan; Chan, Anthony W-H; Leung, Howard H-W; Wong, Grace L-H; Yu, Simon C-H; Chu, Winnie C-W; Chen, Weitian.
Afiliação
  • Hou J; Department of Imaging and Interventional Radiology, Chinese University of Hong Kong, Hong Kong.
  • Wong VW; Department of Medicine and Therapeutics, Chinese University of Hong Kong, Hong Kong.
  • Qian Y; State Key Laboratory of Digestive Disease, Chinese University of Hong Kong, Hong Kong.
  • Jiang B; Medical Data Analytics Centre, Chinese University of Hong Kong, Hong Kong.
  • Chan AW; Department of Imaging and Interventional Radiology, Chinese University of Hong Kong, Hong Kong.
  • Leung HH; Department of Imaging and Interventional Radiology, Chinese University of Hong Kong, Hong Kong.
  • Wong GL; Department of Anatomical and Cellular Pathology, Chinese University of Hong Kong, Hong Kong.
  • Yu SC; Department of Anatomical and Cellular Pathology, Chinese University of Hong Kong, Hong Kong.
  • Chu WC; Department of Medicine and Therapeutics, Chinese University of Hong Kong, Hong Kong.
  • Chen W; State Key Laboratory of Digestive Disease, Chinese University of Hong Kong, Hong Kong.
J Magn Reson Imaging ; 57(2): 485-492, 2023 02.
Article em En | MEDLINE | ID: mdl-35753084
ABSTRACT

BACKGROUND:

Liver fibrosis is characterized by macromolecule depositions. Recently, a novel technology termed macromolecular proton fraction quantification based on spin-lock magnetic resonance imaging (MPF-SL) is reported to measure macromolecule levels.

HYPOTHESIS:

MPF-SL can detect early-stage liver fibrosis by measuring macromolecule levels in the liver. STUDY TYPE Retrospective.

SUBJECTS:

Fifty-five participants, including 22 with no fibrosis (F0) and 33 with early-stage fibrosis (F1-2), were recruited. FIELD STRENGTH/SEQUENCE 3 T; two-dimensional (2D) MPF-SL turbo spin-echo sequence, 2D spin-lock T1rho turbo spin-echo sequence, and multi-slice 2D gradient echo sequence. ASSESSMENT Macromolecular proton fraction (MPF), T1rho, liver iron concentration (LIC), and fat fraction (FF) biomarkers were quantified within regions of interest. STATISTICAL TESTS Group comparison of the biomarkers using Mann-Whitney U tests; correlation between the biomarkers assessed using Spearman's rank correlation coefficient and linear regression with goodness-of-fit; fibrosis stage differentiation using receiver operating characteristic curve (ROC) analysis. P-value < 0.05 was considered statistically significant.

RESULTS:

Average T1rho was 41.76 ± 2.94 msec for F0 and 41.15 ± 3.73 msec for F1-2 (P = 0.60). T1rho showed nonsignificant correlation with either liver fibrosis (ρ = -0.07; P = 0.61) or FF (ρ = -0.14; P = 0.35) but indicated a negative correlation with LIC (ρ = -0.66). MPF was 4.73 ± 0.45% and 5.65 ± 0.81% for F0 and F1-2 participants, respectively. MPF showed a positive correlation with liver fibrosis (ρ = 0.59), and no significant correlations with LIC (ρ = 0.02; P = 0.89) or FF (ρ = 0.05; P = 0.72). The area under the ROC curve was 0.85 (95% confidence interval [CI] 0.75-0.95) and 0.55 (95% CI 0.39-0.71; P = 0.55) for MPF and T1rho to discriminate between F0 and F1-2 fibrosis, respectively. DATA

CONCLUSION:

MPF-SL has the potential to diagnose early-stage liver fibrosis and does not appear to be confounded by either LIC or FF. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY STAGE 3.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótons / Cirrose Hepática Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Hong Kong

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótons / Cirrose Hepática Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Hong Kong