Your browser doesn't support javascript.
loading
Femtoliter-Droplet Mass Spectrometry Interface Utilizing Nanofluidics for Ultrasmall and High-Sensitivity Analysis.
Takagi, Yuto; Kazoe, Yutaka; Morikawa, Kyojiro; Kitamori, Takehiko.
Afiliação
  • Takagi Y; Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.
  • Kazoe Y; Department of System Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan.
  • Morikawa K; Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.
  • Kitamori T; Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan R. O. C.
Anal Chem ; 94(28): 10074-10081, 2022 07 19.
Article em En | MEDLINE | ID: mdl-35793145
ABSTRACT
In the fields of biology and medicine, comprehensive protein analysis at the single-cell level utilizing mass spectrometry (MS) with pL sample volumes and zmol to amol sensitivity is required. Our group has developed nanofluidic analytical pretreatment methods that exploit nanochannels for downsizing chemical unit operations to fL-pL volumes. In the field of analytical instruments, mass spectrometers have advanced to achieve ultrahigh sensitivity. However, a method to interface between fL-pL pretreatments and mass spectrometers without sample loss and dispersion is still challenging. In this study, we developed an MS interface utilizing nanofluidics to achieve high-sensitivity detection. After charging analyte molecules by an applied voltage through an electrode, the liquid sample was converted to fL droplets by a nanofluidic device. Considering the inertial force that acts on the droplets, the droplets were carried with a controlled trajectory, even in turbulent air flow, and injected into a mass spectrometer with 100% efficiency. A module for heat transfer was designed and constructed, by which all of the injected droplets were vaporized to produce gas-phase ions. The detection of caffeine ions was achieved at a limit of detection of 1.52 amol, which was 290 times higher than a conventional MS interface by electrospray ionization with sample dispersion combined with a similar mass spectrometer. Therefore, sensitivity that was 2 orders of magnitude higher could be realized due to the 100% sample injection rate. The present study provides a new methodology for the analysis of ultrasmall samples with high-sensitivity, such as protein molecules produced from a single cell.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão