Your browser doesn't support javascript.
loading
Heart Rate-Dependent Degree of Motion Artifacts in Coronary CT Angiography Acquired by a Novel Purpose-Built Cardiac CT Scanner.
Vecsey-Nagy, Milán; Jermendy, Ádám Levente; Kolossváry, Márton; Vattay, Borbála; Boussoussou, Melinda; Suhai, Ferenc Imre; Panajotu, Alexisz; Csore, Judit; Borzsák, Sarolta; Fontanini, Daniele Mariastefano; Csobay-Novák, Csaba; Merkely, Béla; Maurovich-Horvat, Pál; Szilveszter, Bálint.
Afiliação
  • Vecsey-Nagy M; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Jermendy ÁL; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Kolossváry M; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Vattay B; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Boussoussou M; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Suhai FI; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Panajotu A; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Csore J; Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Borzsák S; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Fontanini DM; Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Csobay-Novák C; Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Merkely B; Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Maurovich-Horvat P; MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary.
  • Szilveszter B; Medical Imaging Centre, Semmelweis University, 1082 Budapest, Hungary.
J Clin Med ; 11(15)2022 Jul 26.
Article em En | MEDLINE | ID: mdl-35893427
ABSTRACT
Although reaching target heart rate (HR) before coronary CT angiography (CCTA) is still of importance, adequate HR control remains a challenge for many patients. Purpose-built cardiac scanners may provide optimal image quality at higher HRs by further improving temporal resolution. We aimed to compare the amount of motion artifacts on CCTA acquired using a dedicated cardiac CT (DCCT) compared to a conventional multidetector CT (MDCT) scanner. We compared 80 DCCT images to 80 MDCT scans matched by sex, age, HR, and coronary dominance. Image quality was graded on a per-patient, per-vessel and per-segment basis. Motion artifacts were assessed using Likert scores (1 non-diagnostic, 2 severe artifacts, 3 mild artifacts, 4 no artifacts). Patients were stratified into four groups according to HR (<60/min, 60−65/min, 66−70/min and >70/min). Overall, 2328 coronary segments were evaluated. DCCT demonstrated superior overall image quality compared to MDCT (3.7 ± 0.4 vs. 3.3 ± 0.7, p < 0.001). DCCT images yielded higher Likert scores in all HR ranges, which was statistically significant in the 60−65/min, 66−70/min and >70/min ranges (3.9 ± 0.2 vs. 3.7 ± 0.2, p = 0.008; 3.5 ± 0.5 vs. 3.1 ± 0.6, p = 0.048 and 3.5 ± 0.4 vs. 2.7 ± 0.7, p < 0.001, respectively). Using a dedicated cardiac scanner results in fewer motion artifacts, which may allow optimal image quality even in cases of high HRs.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Hungria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Hungria