Your browser doesn't support javascript.
loading
Direct Conversion X-ray Detector with Micron-Scale Pixel Pitch for Edge-Illumination and Propagation-Based X-ray Phase-Contrast Imaging.
Pil-Ali, Abdollah; Adnani, Sahar; Scott, Christopher C; Karim, Karim S.
Afiliação
  • Pil-Ali A; Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
  • Adnani S; Centre for Bioengineering and Biotechnology, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
  • Scott CC; Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
  • Karim KS; Centre for Bioengineering and Biotechnology, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
Sensors (Basel) ; 22(15)2022 Aug 07.
Article em En | MEDLINE | ID: mdl-35957449
ABSTRACT
In this work, we investigate the potential of employing a direct conversion integration mode X-ray detector with micron-scale pixels in two different X-ray phase-contrast imaging (XPCi) configurations, propagation-based (PB) and edge illumination (EI). Both PB-XPCi and EI-XPCi implementations are evaluated through a wave optics model-numerically simulated in MATLAB-and are compared based on their contrast, edge-enhancement, visibility, and dose efficiency characteristics. The EI-XPCi configuration, in general, demonstrates higher performance compared to PB-XPCi, considering a setup with the same X-ray source and detector. However, absorption masks quality (thickness of X-ray absorption material) and environmental vibration effect are two potential challenges for EI-XPCi employing a detector with micron-scale pixels. Simulation results confirm that the behavior of an EI-XPCi system employing a high-resolution detector is susceptible to its absorption masks thickness and misalignment. This work demonstrates the potential and feasibility of employing a high-resolution direct conversion detector for phase-contrast imaging applications where higher dose efficiency, higher contrast images, and a more compact imaging system are of interest.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iluminação Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iluminação Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá