Your browser doesn't support javascript.
loading
Assessing muscle-specific potassium concentrations in human lower leg using potassium magnetic resonance imaging.
Gast, Lena V; Baier, Laura-Marie; Chaudry, Oliver; Meixner, Christian R; Müller, Max; Engelke, Klaus; Uder, Michael; Heiss, Rafael; Nagel, Armin M.
Afiliação
  • Gast LV; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Baier LM; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Chaudry O; Department of Medicine 3, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Meixner CR; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Müller M; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Engelke K; Department of Medicine 3, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Uder M; Institute of Medical Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Heiss R; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Nagel AM; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
NMR Biomed ; 36(1): e4819, 2023 01.
Article em En | MEDLINE | ID: mdl-35994248
ABSTRACT
Noninvasively assessing tissue potassium concentrations (TPCs) using potassium magnetic resonance imaging (39 K MRI) could give valuable information on physiological processes connected to various pathologies. However, because of inherently low 39 K MR image resolution and strong signal blurring, a reliable measurement of the TPC is challenging. The aim of this work was to investigate the feasibility of a muscle-specific TPC determination with a focus on the influence of a varying residual quadrupolar interaction in human lower leg muscles. The quantification accuracy of a muscle-specific TPC determination was first assessed using simulated 39 K MRI data. In vivo 39 K and corresponding sodium (23 Na) MRI data of healthy lower leg muscles (n = 14, seven females) were acquired on a 7-T MR system using a double-resonant 23 Na/39 K birdcage Tx/Rx RF coil. Additional 1 H MR images were acquired on a 3-T MR system and used for tissue segmentation. Quantification of TPC was performed after a region-based partial volume correction (PVC) using five external reference phantoms. Simulations not only underlined the importance of PVC for correctly assessing muscle-specific TPC values, but also revealed the strong impact of a varying residual quadrupolar interaction between different muscle regions on the measured TPC. Using 39 K T2 * decay curves, we found significantly higher residual quadrupolar interaction in tibialis anterior muscle (TA; ωq = 194 ± 28 Hz) compared with gastrocnemius muscle (medial/lateral head, GM/GL; ωq = 151 ± 25 Hz) and soleus muscle (SOL; ωq = 102 ± 32 Hz). If considered in the PVC, TPC in individual muscles was similar (TPC = 98 ± 11/96 ± 14/99 ± 8/100 ± 12 mM in GM/GL/SOL/TA). Comparison with tissue sodium concentrations suggested that residual quadrupolar interactions might also influence the 23 Na MRI signal of lower leg muscles. A TPC determination of individual lower leg muscles is feasible and can therefore be applied in future studies. Considering a varying residual quadrupolar interaction for PVC of 39 K MRI data is essential to reliably assess potassium concentrations in individual muscles.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potássio / Músculos Limite: Humans Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potássio / Músculos Limite: Humans Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha