Flow patterns in the venous sinus of pulsatile tinnitus patients with transverse sinus stenosis and underlying vortical flow as a causative factor.
Comput Methods Programs Biomed
; 227: 107203, 2022 Dec.
Article
em En
| MEDLINE
| ID: mdl-36370596
BACKGROUND: Transverse sinus stenosis (TSS) is commonly found in Pulsatile Tinnitus (PT) patients. Vortex flow is prominent in venous sinus with stenosis, and so it is important to determine the distribution and strength of the vortical flow to understand its influence on the occurrence of PT. METHODS: In this study, by using computational fluid dynamics for hemodynamic analysis in patient-specific geometries based on Magnetic Resonance Imaging (MRI), we have investigated the blood flow within the venous sinus of 16 subjects with PT. We have employed both laminar and turbulent flow models for simulations, to obtain (i) streamlines of velocity distribution in the venous sinus, and (ii) pressure distributions of flow patterns in the venous sinus. Then, hemodynamic analysis in the venous sinus recirculation zone was carried out, to determine the flow patterns at the junction of transverse sinuses and sigmoid sinuses. Finally, we have proposed a new model for turbulence evaluation based on the regression analysis of anatomic and hemodynamics parameters. RESULTS: Correlation analysis between the anatomical parameters and the hemodynamic parameters has shown that stenosis at the transverse sinus was the main factor in the local hemodynamics variation in the venous sinus of patients; in this context, it is shown that vorticity can be used as a prime indicator of the severity of the stenosis function. Our results have shown a significant correlation between the vorticity and the stenotic maximum velocity (SMV) (r = 0.282, p = 0.004). Then, a parameterized prediction model is proposed to determine the vorticity in terms of flow and anatomic variables, termed as the turbulence eddy prediction model (TEP model). Our result have shown that the TEP model is sensitive to the dominant flow distribution, with a high correlation to the flow-based vorticity (r = 0.809, p = 0.009). CONCLUSIONS: The quantification of the vorticity (as both vorticity and MVV) in the downstream of TSS could be a marker for indication of turbulent energy at the transverse-sigmoid sinus, which could potentially serve as a hemodynamic marker for the functional assessment of the PT-related TSS.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Zumbido
/
Seios Transversos
Tipo de estudo:
Prognostic_studies
Limite:
Humans
Idioma:
En
Revista:
Comput Methods Programs Biomed
Assunto da revista:
INFORMATICA MEDICA
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
China