Your browser doesn't support javascript.
loading
Spatio-temporal optical coherence tomography provides full thickness imaging of the chorioretinal complex.
Auksorius, Egidijus; Borycki, Dawid; Wegrzyn, Piotr; Sikorski, Bartosz L; Lizewski, Kamil; Zickiene, Ieva; Rapolu, Mounika; Adomavicius, Karolis; Tomczewski, Slawomir; Wojtkowski, Maciej.
Afiliação
  • Auksorius E; International Center for Translational Eye Research (ICTER), ul. Skierniewicka 10a, 01-230 Warsaw, Poland.
  • Borycki D; Center for Physical Sciences and Technology (FTMC), Sauletekio al. 3, LT-10257 Vilnius, Lithuania.
  • Wegrzyn P; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland.
  • Sikorski BL; International Center for Translational Eye Research (ICTER), ul. Skierniewicka 10a, 01-230 Warsaw, Poland.
  • Lizewski K; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland.
  • Zickiene I; International Center for Translational Eye Research (ICTER), ul. Skierniewicka 10a, 01-230 Warsaw, Poland.
  • Rapolu M; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland.
  • Adomavicius K; Faculty of Physics, University of Warsaw, Pasteura 5, 02-093 Warsaw, Poland.
  • Tomczewski S; Department of Ophthalmology, Nicolaus Copernicus University, Sklodowskiej-Curie 9, 85-090 Bydgoszcz, Poland.
  • Wojtkowski M; Oculomedica, Eye Research & Development Center, Ogrody 14, 85-870 Bydgoszcz, Poland.
iScience ; 25(12): 105513, 2022 Dec 22.
Article em En | MEDLINE | ID: mdl-36419849
ABSTRACT
Despite the rapid development of optical imaging methods, high-resolution in vivo imaging with penetration into deeper tissue layers is still a major challenge. Optical coherence tomography (OCT) has been used successfully for non-invasive human retinal volumetric imaging in vivo, advancing the detection, diagnosis, and monitoring of various retinal diseases. However, there are important limitations of volumetric OCT imaging, especially coherent noise and the limited axial range over which high resolution images can be acquired. The limited range prevents simultaneous measurement of the retina and choroid with adequate lateral resolution. In this article, we address these limitations with a technique that we term spatio-temporal optical coherence tomography (STOC-T), which uses light with controlled spatial and temporal coherence and advanced signal processing methods. STOC-T enabled the acquisition of high-contrast and high-resolution coronal projection images of the retina and choroid at arbitrary depths.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: IScience Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: IScience Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Polônia