Your browser doesn't support javascript.
loading
Dip-coating electromechanically active polymer actuators with SIBS from midblock-selective solvents to achieve full encapsulation for biomedical applications.
Rinne, Pille; Põldsalu, Inga; Zadin, Veronika; Johanson, Urmas; Tamm, Tarmo; Põhako-Esko, Kaija; Punning, Andres; van den Ende, Daan; Aabloo, Alvo.
Afiliação
  • Rinne P; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia. pille.rinne@eesti.ee.
  • Põldsalu I; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia.
  • Zadin V; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia.
  • Johanson U; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia.
  • Tamm T; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia.
  • Põhako-Esko K; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia.
  • Punning A; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia.
  • van den Ende D; Smart Interfaces & Modules Department, Philips Research, Eindhoven, The Netherlands.
  • Aabloo A; Institute of Technology, University of Tartu, Nooruse 1, 50411, Tartu, Estonia.
Sci Rep ; 12(1): 21589, 2022 12 14.
Article em En | MEDLINE | ID: mdl-36517538
ABSTRACT
Soft and compliant ionic electromechanically active polymer actuators (IEAPs) are a promising class of smart materials for biomedical and soft robotics applications. These materials change their shape in response to external stimuli like the electrical signal. This shape-change results solely from the ion flux inside the composite and hence the material can be miniaturized below the centimeter and millimeter levels-something that still poses a challenge for many other conventional actuation mechanisms in soft robotics (e.g., pneumatic, hydraulic, or tendon-based systems). However, the components used to prepare IEAPs are typically not safe for the biological environment, nor is the environment safe for the actuator. Safety concerns and unreliable operation in foreign liquid environments have been some of the main obstacles for the widespread adoption of IEAPs in many areas, e.g., in biomedical applications. Here we show a novel approach to fully encapsulate IEAP actuators with the biocompatible block copolymer SIBS (poly(styrene-block-isobutylene-block-styrene)) dissolved in block-selective solvents. Reduction in the bending amplitude due to the added passive layers, a common negative side-effect of encapsulating IEAPs, was not observed in this work. In conclusion, the encapsulated actuator is steered through a tortuous vasculature mock-up filled with a viscous buffer solution mimicking biological fluids.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Robótica / Materiais Inteligentes Idioma: En Revista: Sci Rep Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Robótica / Materiais Inteligentes Idioma: En Revista: Sci Rep Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estônia