A New OATP-Mediated Hepatobiliary-Specific Mn(II)-Based MRI Contrast Agent for Hepatocellular Carcinoma in Mice: A Comparison With Gd-EOB-DTPA.
J Magn Reson Imaging
; 58(3): 926-933, 2023 09.
Article
em En
| MEDLINE
| ID: mdl-36609994
BACKGROUND: Growing concerns about the safety of gadolinium (Gd)-based contrast agents have reinforced the need for the development of Gd-free MRI contrast agents (CAs) that are effective in imaging liver tumors. PURPOSE: To evaluate the ability of Mn-BnO-TyEDTA MRI CA to detect hepatocellular carcinoma in a mouse model of implanted liver tumor. STUDY TYPE: Prospective. ANIMAL MODEL: Thirteen orthotopically implanted liver tumor mice. FIELD STRENGTH/SEQUENCE: 3.0 T/precontrast and postcontrast T1-weighted fast spoiled gradient recalled echo and T2-weighted fast recovery fast spin-echo imaging with fat suppression. ASSESSMENT: The relative enhancement ratio was calculated and statistically compared. Lesion detection in postcontrast images was analyzed by calculations of area under the curve (AUC, the increases in liver-to-tumor contrast-to-noise ratio [∆CNR] vs. time curve). Mn or Gd levels were measured in the liver and tumoral tissues by inductively coupled plasma-mass spectrometry. Tumor specimens were stained with hematoxylin and eosin (H&E) and the expression of organic anion transfer peptide (OATP)1B1 was evaluated by immunofluorescence (IF) staining and mean fluorescence intensity (MFI) was calculated. STATISTICAL TESTS: Unpaired t-test and two-tailed paired t-test. P < 0.05 was considered statistical significance. RESULTS: Mn-BnO-TyEDTA and Gd-EOB-DTPA demonstrated nearly identical enhancement patterns in the liver, tumor, and psoas muscle and no difference in lesion detection (AUC10-30, Mn = 851 ∆CR·min, AUC10-30, Gd = 823 ∆CR·min). A Significant higher concentration of metal (Mn or Gd) was found in the liver compared to the tumor ([Mn]liver = 0.88 ± 0.07 µmmol/g, [Mn]tumor = 0.49 ± 0.05 µmmol/g, [Gd]liver = 0.65 ± 0.07 µmmol/g, [Gd]tumor = 0.27 ± 0.04 µmmol/g). IF staining showed significantly decreased expression of OATP1B1 in the tumor core compared to the liver (MFItumor = 5.28 ± 1.54, MFIliver = 25.49 ± 3.41). DATA CONCLUSION: Mn-BnO-TyEDTA can provide comparable hepatobiliary tumor contrast enhancement to Gd-EOB-DTPA. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Carcinoma Hepatocelular
/
Transportadores de Ânions Orgânicos
/
Neoplasias Hepáticas
Tipo de estudo:
Observational_studies
/
Prognostic_studies
Limite:
Animals
Idioma:
En
Revista:
J Magn Reson Imaging
Assunto da revista:
DIAGNOSTICO POR IMAGEM
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
China