Correction of the urinary testosterone to epitestosterone ratio measurement in antidoping analyses by chromatographic and mass spectrometric techniques.
Martínez Brito, Dayamín; Vidal, Teresa Correa; de la Torre, Xavier; de Oca Porto, Rodny Montes; Botrè, Francesco.
Afiliação
  • Martínez Brito D; Laboratorio Antidoping de la Habana, Analytical Department, Havana, Cuba, Cuba.
  • Vidal TC; Laboratorio Antidoping FMSI, Federazione Medico Sportiva Italiana, Rome, Italy, Italy.
  • de la Torre X; Laboratorio Antidoping de la Habana, Analytical Department, Havana, Cuba, Cuba.
  • de Oca Porto RM; Laboratorio Antidoping FMSI, Federazione Medico Sportiva Italiana, Rome, Italy, Italy.
  • Botrè F; Laboratorio Antidoping de la Habana, Analytical Department, Havana, Cuba, Cuba.
Drug Test Anal ; 15(11-12): 1382-1391, 2023.
Article em En | MEDLINE | ID: mdl-36772848
ABSTRACT
The ratio of testosterone (T) to epitestosterone (E) determined in urine samples is the main biomarker used to prove T and precursors abused by athletes. Analytically, the correction of the ratio is required by the World Anti-Doping Agency. This work describes a series of experiments aimed to study when it is appropriate to correct the T/E ratio value, using different mass spectrometric techniques since only reports on GC-MS exist. Analyses using external calibrators, controls, and routine samples were performed by three different techniques GC-MS, GC-MSn , and LC-MSn . A statistical comparison of the T/E was performed after the application of two corrections previously published Isotopic contribution peak area correction (corr_1) and use of a verified internal deuterated internal standard (TD3/ED3) correction (corr_2) and the ratio based on T and E concentrations. The use of external calibration samples introduces biases that influence not only the T and E concentrations but also the T/E ratio, even when both methods of correction are applied. The correction after applying corr_1 method barely contributed to the accuracy of the T/E calculation. Nevertheless, the application of the corr_2 method increased the accuracy between 5% and 6% when comparing theoretical and experimental T/E values. Finally, the best results were obtained by the ratio calculated directly from the estimated concentrations of T and E. Attention must be paid when the T/E is measured by LC-MSn since different acquisition modes produced significantly different results, even in MS/MS when the same transition is used for T and E.