Your browser doesn't support javascript.
loading
Clinical, microbiological and biochemical impact of a supportive care protocol with an air-polishing device, after surgical treatment of peri-implantitis: Randomized clinical trial.
Luengo, Fernando; Sanz-Esporrín, Javier; Sanz-Sánchez, Ignacio; Solonko, Myroslav; Herrera, David; Sanz, Mariano.
Afiliação
  • Luengo F; ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, University Complutense, Madrid, Spain.
  • Sanz-Esporrín J; ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, University Complutense, Madrid, Spain.
  • Sanz-Sánchez I; ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, University Complutense, Madrid, Spain.
  • Solonko M; Section of Periodontology, Faculty of Odontology, University Complutense, Madrid, Spain.
  • Herrera D; ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, University Complutense, Madrid, Spain.
  • Sanz M; ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, University Complutense, Madrid, Spain.
Clin Oral Implants Res ; 34(4): 378-392, 2023 Apr.
Article em En | MEDLINE | ID: mdl-36789504
ABSTRACT

OBJECTIVES:

The aim of the present study was to evaluate the efficacy of a supportive peri-implant care (SPIC) protocol after surgical therapy of peri-implantitis, combining ultrasonic mechanical debridement and glycine powder air polishing. MATERIALS AND

METHODS:

Thirty subjects diagnosed with peri-implantitis and treated by means of access flap were randomized 6 months later into two different SPIC groups the test group combined a piezoelectric ultrasonic instrumentation with a specific implant PEEK tip and glycine powder air polishing, while control group received the same ultrasonic instrumentation together with a rubber cup and a polishing paste. Patients were followed for 12 months, with intermediate SPIC visits every 3 months. Clinical, radiological, microbiological and biochemical outcome variables were registered and calculated.

RESULTS:

After 12 months of SPIC, probing depths (PD) showed a mean reduction of 0.33 ± 0.11 mm, with significant differences (p < .001) between the test (-0.84 ± 0.43 mm) and the control group (+0.18 ± 0.73 mm). Healthy peri-implant tissues defined by PD <5 mm, absence of BoP (or in only one site around the implant), and no additional bone loss (<0.5 mm), were observed at the final visit in 83% of the implants (87% in the test group and 80% in the control group, p = .255). No adverse events were reported by the subjects participating in the study.

CONCLUSIONS:

The SPIC protocol including mechanical ultrasonic debridement and glycine powder air-polishing demonstrated significantly better efficacy in terms of PD reductions. A strict SPIC protocol can maintain for 1 year, or even improve, the results obtained after surgical treatment of peri-implantitis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Peri-Implantite Tipo de estudo: Clinical_trials / Guideline Limite: Humans Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Peri-Implantite Tipo de estudo: Clinical_trials / Guideline Limite: Humans Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha