Monitoring heparin therapy: stability of two different anti-Xa assays using blood samples collected in citrate-containing and CTAD tubes.
Gremillet, Marion; Talon, Laurie; Lebreton, Aurélien; Sinegre, Thomas.
Afiliação
  • Gremillet M; CHU Clermont-Ferrand, Service d'hématologie Biologique, 1 Place Lucie Et Raymond Aubrac, 63003, Clermont-Ferrand, France.
  • Talon L; CHU Clermont-Ferrand, Service d'hématologie Biologique, 1 Place Lucie Et Raymond Aubrac, 63003, Clermont-Ferrand, France.
  • Lebreton A; CHU Clermont-Ferrand, Service d'hématologie Biologique, 1 Place Lucie Et Raymond Aubrac, 63003, Clermont-Ferrand, France.
  • Sinegre T; Université Clermont Auvergne, Unité de Nutrition Humaine, UMR INRAE/UCA 1019, Clermont-Ferrand, France.
Thromb J ; 21(1): 21, 2023 Feb 20.
Article em En | MEDLINE | ID: mdl-36803983
BACKGROUND: Anti-factor Xa assays and activated partial thromboplastin time (aPTT) are mainly employed to monitor patients treated with heparins. According to the Clinical and Laboratory Standards Institute and the French Working Group on Haemostasis and Thrombosis, anti-factor Xa activity and aPTT should be tested within 2 h of blood sampling for unfractionated heparin (UFH) monitoring. However, discrepancies exist depending on the used reagents and collecting tubes. The study aim was to determine the stability of aPTT and anti-factor Xa measurements using blood samples collected in citrate-containing or citrate-theophylline-adenosine-dipyridamole (CTAD) tubes and stored for up to 6 h. METHODS: Patients receiving UFH or low molecular weight heparin (LMWH) were enrolled; aPTT and anti-factor Xa activity were tested using two different analyser/reagent pairs (Stago and reagent without dextran sulfate; Siemens and reagent with dextran sulfate) after 1, 4 and 6 h of sample storage as whole blood or as plasma. RESULTS: For UFH monitoring, comparable anti-factor Xa activity and aPTT results were obtained with both analyser/reagent pairs when samples were stored as whole blood before plasma isolation. With samples stored as plasma, anti-factor Xa activity and aPTT were not affected up to 6 h after sampling when using the Stago/no-dextran sulfate reagent pair. With the Siemens/dextran sulfate-containing reagent, aPTT was significantly altered after 4 h of storage. For LMWH monitoring, anti-factor Xa activity remained stable (whole blood and plasma) for at least 6 h. Results were comparable with citrate-containing and CTAD tubes. CONCLUSIONS: Anti-factor Xa activity in samples stored as whole blood or plasma was stable for up to 6 h, regardless of the reagent (with/without dextran sulfate)/collection tube. Conversely, aPTT was more variable because other plasma parameters can influence its measure and complicate the interpretation of its variations after 4 h.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Thromb J Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França