Your browser doesn't support javascript.
loading
High-Precision 3D Reconstruction Study with Emphasis on Refractive Calibration of GelStereo-Type Sensors.
Zhang, Chaofan; Cui, Shaowei; Wang, Shuo; Hu, Jingyi; Huangfu, Yipeng; Zhang, Boyue.
Afiliação
  • Zhang C; State Key Laboratory of Multimodal Artificial Intelligence Systems, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China.
  • Cui S; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Wang S; State Key Laboratory of Multimodal Artificial Intelligence Systems, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China.
  • Hu J; State Key Laboratory of Multimodal Artificial Intelligence Systems, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China.
  • Huangfu Y; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhang B; Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences, Shanghai 200031, China.
Sensors (Basel) ; 23(5)2023 Feb 28.
Article em En | MEDLINE | ID: mdl-36904879
ABSTRACT
GelStereo sensing technology is capable of performing three-dimensional (3D) contact shape measurement under various contact structures such as bionic curved surfaces, which has promising advantages in the field of visuotactile sensing. However, due to multi-medium ray refraction in the imaging system, robust and high-precision tactile 3D reconstruction remains a challenging problem for GelStereo-type sensors with different structures. In this paper, we first propose a universal Refractive Stereo Ray Tracing (RSRT) model for GelStereo-type sensing systems to realize 3D reconstruction of the contact surface. Moreover, a relative geometry-based optimization method is presented to calibrate multiple parameters of the proposed RSRT model, such as the refractive indices and structural dimensions. Furthermore, extensive quantitative calibration experiments are performed on four different GelStereo sensing platforms; the experimental results show that the proposed calibration pipeline can achieve less than 0.35 mm in Euclidean distance error, based on which we believe that the proposed refractive calibration method can be further applied in more complex GelStereo-type and other similar visuotactile sensing systems. Such high-precision visuotactile sensors can facilitate the study of robotic dexterous manipulation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China