Your browser doesn't support javascript.
loading
Relative Permittivity Measurement of Microliter Volume Liquid Samples through Microwave Filters.
Yasin, Azhar; Gogosh, Nayab; Sohail, Syed Irfan; Abbas, Syed Muzahir; Shafique, Muhammad Farhan; Mahmoud, Abdelhady.
Afiliação
  • Yasin A; Department of Electrical and Computer Engineering, COMSATS University Islamabad, Islamabad 45550, Pakistan.
  • Gogosh N; Department of Electrical and Computer Engineering, COMSATS University Islamabad, Islamabad 45550, Pakistan.
  • Sohail SI; Department of Computing and Technology, IQRA University Islamabad Campus, Islamabad 44000, Pakistan.
  • Abbas SM; Faculty of Science and Engineering, School of Engineering, Macquarie University, Sydney, NSW 2109, Australia.
  • Shafique MF; Center for Advanced Studies in Telecommunication, COMSATS University Islamabad, Islamabad 45550, Pakistan.
  • Mahmoud A; Benha Faculty of Engineering, Benha University, Benha 13512, Egypt.
Sensors (Basel) ; 23(6)2023 Mar 07.
Article em En | MEDLINE | ID: mdl-36991594
ABSTRACT
This paper proposes a concept of dielectric characterization of low-volume liquid samples using the coupling coefficient of filters. The concept is validated through a two-pole substrate integrated waveguide filter in which the liquid under test is mounted on the coupling section between the two resonators. Unlike the conventional resonator perturbation method reported many times in the literature, this technique uses the coupling coefficient for sensing. The liquid sample is collected in a capillary tube and carefully positioned on the coupling section of the filter; the coupling coefficient of the two resonators varies compared to the relative permittivity of the sample; thus, an empirical model is established. The proposed sensor has been tested to compute the permittivity of different alcohols. Binary solutions of ethanol and water have also been characterized to calculate the volume ratio and relative permittivity as a proof-of-concept. The obtained results show that the proposed sensing technique is capable of characterizing a low quantity of liquids (≈44 µL) with good accuracy, and a worst case measured error of only 6.8% is noted. The ease of integration with other circuitry, low cost, reusability with no deterioration, and adaptability of the proposed sensor makes it a suitable choice for the chemical as well as for the pharmaceutical industry.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Paquistão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Paquistão