Your browser doesn't support javascript.
loading
Predictive value of NoSAS questionnaire combined with the modified Mallampati grade for hypoxemia during routine sedation for gastrointestinal endoscopy.
Li, Nana; Wu, Junbei; Lu, Yunhong; Zhang, Jigang; Sun, Zhaochu; Cao, Xiaofei; Liu, Cunming.
Afiliação
  • Li N; Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Wu J; Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Lu Y; Department of Anesthesiology, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Zhang J; Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Sun Z; Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Cao X; Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China. xiaofei_cao@njmu.edu.cn.
  • Liu C; Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China. cunmingliu@njmu.edu.cn.
BMC Anesthesiol ; 23(1): 126, 2023 04 17.
Article em En | MEDLINE | ID: mdl-37069514
ABSTRACT

BACKGROUND:

The incidence of hypoxemia during painless gastrointestinal endoscopy remains a matter of concem. To date, there is no recognized simple method to predict hypoxemia in digestive endoscopic anesthesia. The NoSAS (neck circumference, obesity, snoring, age, sex) questionnaire, an objective and simple assessment scale used to assess obstructive sleep apnea (OSA), combined with the modified Mallampati grade (MMP), may have certain screening value. This combination may allow anesthesiologists to anticipate, manage, and consequently decrease the occurrence of hypoxemia.

METHODS:

This study was a prospective observational trial. The primary endpoint was the incidence of hypoxaemia defined as pulse oxygen saturation (SpO2) < 95% for 10 s. A total of 2207 patients admitted to our hospital for painless gastrointestinal endoscopy were studied. All patients were measured for age, height, weight, body mass index, neck circumference, snoring, MMP, and other parameters. Patients were divided into hypoxemic and non-hypoxemic groups based on the SpO2. The ROC curve was plotted to evaluate the screening value of the NoSAS questionnaire separately and combined with MMP for hypoxemia. The total NoSAS score was evaluated at cut-off points of 8 and 9.

RESULTS:

With a NoSAS score ≥ 8 as the critical value for analysis, the sensitivity for hypoxemia was 58.3%, the specificity was 88.4%, and the area under the ROC was 0.734 (P < 0.001, 95% CI 0.708-0.759). With a NoSAS score ≥ 9 as a critical value, the sensitivity for hypoxemia was 36.50%, the specificity rose to 96.16%, and the area under the ROC was 0.663 (P < 0.001, 95% CI 0.639-0.688). With the NoSAS Score combined with MMP for analysis, the sensitivity was 78.4%, the specificity was 84%, and the area under the ROC was 0.859 (P < 0.001, 95%CI0.834-0.883).

CONCLUSIONS:

As a new screening tool, the NoSAS questionnaire is simple, convenient, and useful for screening hypoxemia. This questionnaire, when paired withMMP, is likely to be helpful for the screening of hypoxemia.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ronco / Anestesia Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: BMC Anesthesiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ronco / Anestesia Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: BMC Anesthesiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China