Your browser doesn't support javascript.
loading
Point-of-Care and Dual-Response Detection of Hydrazine/Hypochlorite-Based on a Smart Hydrogel Sensor and Applications in Information Security and Bioimaging.
Du, Man; Zhang, Yue; Xu, Zhice; Dong, Zhipeng; Zhao, Shuchun; Du, Hongxia; Zhao, Hua.
Afiliação
  • Du M; College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China.
  • Zhang Y; College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China.
  • Xu Z; College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China.
  • Dong Z; Hebei Lansheng Biotech Co., Ltd., Shijiazhuang 052260, China.
  • Zhao S; College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China.
  • Du H; College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China.
  • Zhao H; College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China.
Molecules ; 28(9)2023 May 05.
Article em En | MEDLINE | ID: mdl-37175308
ABSTRACT
A novel dual-response fluorescence probe (XBT-CN) was developed by using a fluorescence priming strategy for quantitative monitoring and visualization of hydrazine (N2H4) and hypochlorite (ClO-). With the addition of N2H4/ClO-, the cleavage reaction of C=C bond initiated by N2H4/ClO- was transformed into corresponding hydrazone and aldehyde derivatives, inducing the probe XBT-CN appeared a fluorescence "off-on" response, which was verified by DFT calculation. HRMS spectra were also conducted to confirm the sensitive mechanism of XBT-CN to N2H4 and ClO-. The probe XBT-CN had an obvious fluorescence response to N2H4 and ClO-, which caused a significant color change in unprotected eyes. In addition, the detection limits of XBT-CN for N2H4 and ClO- were 27 nM and 34 nM, respectively. Interference tests showed that other competitive analytes could hardly interfere with the detection of N2H4 and ClO- in a complex environment. In order to realize the point-of-care detection of N2H4 and ClO-, an XBT-CN@hydrogel test kit combined with a portable smartphone was developed. Furthermore, the portable test kit has been applied to the detection of N2H4 and ClO- in a real-world environment and food samples, and a series of good results have been achieved. Attractively, we demonstrated that XBT-CN@hydrogel was successfully applied as an encryption ink in the field of information security. Finally, the probe can also be used to monitor and distinguish N2H4 and ClO- in living cells, exhibiting excellent biocompatibility and low cytotoxicity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Hipocloroso / Hidrogéis Tipo de estudo: Diagnostic_studies Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Hipocloroso / Hidrogéis Tipo de estudo: Diagnostic_studies Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China