A methodology to abridge microdosimetric distributions without a significant loss of the spectral information needed for the RBE computation in carbon ion therapy.
J Appl Clin Med Phys
; 24(7): e14049, 2023 Jul.
Article
em En
| MEDLINE
| ID: mdl-37227694
BACKGROUND: In order to compute the relative biological effectiveness (RBE) of ion radiation therapy with the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM), it is necessary to process entire microdosimetric distributions. Therefore, a posteriori RBE recalculations (i.e., for a different cell line or another biological endpoint) would require whole spectral information. It is currently not practical to compute and store all this data for each clinical voxel. PURPOSE: To develop a methodology that allows to store a limited amount of physical information without losing accuracy in the RBE calculations nor the possibility of a posteriori RBE recalculations. METHODS: Computer simulations for four monoenergetic 12 C ion beams and a 12 C ion spread-out Bragg peak (SOBP) were performed to assess lineal energy distributions as a function of the depth within a water phantom. These distributions were used in combination with the MCF MKM to compute the in vitro clonogenic survival RBE for human salivary gland tumor cells (HSG cell line) and human skin fibroblasts (NB1RGB cell line). The RBE values were also calculated with a new abridged microdosimetric distribution methodology (AMDM) and compared with the reference RBE calculations using the entire distributions. RESULTS: The maximum relative deviation between the RBE values computed using the entire distributions and the AMDM was 0.61% (monoenergetic beams) and 0.49% (SOBP) for the HSG cell line, while 0.45% (monoenergetic beams) and 0.26% (SOBP) for the NB1RGB cell line. CONCLUSION: The excellent agreement between the RBE values computed using the entire lineal energy distributions and the AMDM represents a milestone for the clinical implementation of the MCF MKM.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Radioterapia com Íons Pesados
Limite:
Humans
Idioma:
En
Revista:
J Appl Clin Med Phys
Assunto da revista:
BIOFISICA
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
Estados Unidos