[Efficacy of a latex Foley catheter with sustained release of chlorhexidine: 1st report: Clinical trials for the prevention of urinary tract infection].
Hinyokika Kiyo
; 32(4): 567-74, 1986 Apr.
Article
em Ja
| MEDLINE
| ID: mdl-3739862
Seventy five patients requiring urethral catheterization for over 24 hours were treated with a latex Foley catheter with sustained release of chlorhexidine in a closed drainage system. While the catheter was indwelling, urinary concentrations of chlorhexidine were maintained at the level of 1 to 2 micrograms/ml in average in almost all patients. The catheter was highly effective in preventing the acquisition of catheter-associated bacteriuria in patients with initially sterile urine without systemic antimicrobial therapy. The acquisition rate of bacteriuria was 8, 16, 23, 35 and 74% on day 3, 4, 5, 6 and 7 with the catheter indwelling, respectively. The catheter was not effective in eradicating preexisting bacteriuria. Complications of the catheter were minimal.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Bacteriúria
/
Cateterismo Urinário
/
Clorexidina
/
Anti-Infecciosos Urinários
Tipo de estudo:
Etiology_studies
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Ja
Revista:
Hinyokika Kiyo
Ano de publicação:
1986
Tipo de documento:
Article