Your browser doesn't support javascript.
loading
Development of a sensitive LC-MS/MS method for the quantification of theranostic agent cypate in mouse plasma and application to a pharmacokinetic study.
Bo, Zheyue; Han, Wanjun; Zhao, Haoyue; Liu, Han; Liang, Ting; Li, Lanjing; Peng, Taotao; Li, Ying; Gui, Chunshan.
Afiliação
  • Bo Z; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Han W; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Zhao H; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Liu H; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Liang T; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Li L; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Peng T; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Li Y; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China.
  • Gui C; College of Pharmaceutical Sciences, Soochow University, 199 Renai Road, Suzhou Industrial Park, Suzhou 215123, China. Electronic address: guichunshan@suda.edu.cn.
Article em En | MEDLINE | ID: mdl-37413828
ABSTRACT
Cypate, a heptamethine cyanine dye, is a prototypic near-infrared (NIR) theranostic agent for optical imaging and photothermal therapy. In the present study, a selective, sensitive, and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitation of cypate in mouse plasma. The chromatographic separation was achieved using a short C18 column (2.1 mm × 50 mm, 5 µm) with a run time of 5 min. The MS was operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization. The ion transitions for cypate and internal standard IR-820 were m/z 626.3 â†’ 596.3 and m/z 827.4 â†’ 330.2, respectively. The method was linear over a concentration range of 1.0-500 ng/mL. The within-run and between-run precision was less than 14.4% with accuracy in the range of -13.4% ∼ 9.8%. The validated method was successfully applied to a pharmacokinetic study of cypate in mice following intravenous administration.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China