Your browser doesn't support javascript.
loading
Electromagnetic pulse protective shielding for digital x-ray detectors.
Schreiner, Stephan; Rauch, Constantin; Akstaller, Bernhard; Bleuel, Paulina; Fröjdh, Eric; Martynenko, Artem S; Mozzanica, Aldo; Neumayer, Paul; Wegert, Leonard; Zielbauer, Bernhard; Zink, Adrian; Anton, Gisela; Michel, Thilo; Funk, Stefan.
Afiliação
  • Schreiner S; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
  • Rauch C; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
  • Akstaller B; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
  • Bleuel P; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
  • Fröjdh E; Paul Scherrer Institut (Psi), Forschungsstrasse 111, 5232 Villigen, Switzerland.
  • Martynenko AS; Gsi Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt, Germany.
  • Mozzanica A; Paul Scherrer Institut (Psi), Forschungsstrasse 111, 5232 Villigen, Switzerland.
  • Neumayer P; Gsi Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt, Germany.
  • Wegert L; Gsi Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt, Germany.
  • Zielbauer B; Gsi Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt, Germany.
  • Zink A; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
  • Anton G; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
  • Michel T; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
  • Funk S; Erlangen Centre for Astroparticle Physics (Ecap), Friedrich-Alexander Universität Erlangen-Nürnberg, Nikolaus-Fiebiger-Straße 2, 91058 Erlangen, Germany.
Rev Sci Instrum ; 94(7)2023 Jul 01.
Article em En | MEDLINE | ID: mdl-37477554
ABSTRACT
Laser-driven x-ray backlighting can be used to image fast dynamic processes like the propagation of laser-driven shock waves in matter. We demonstrate and evaluate the feasibility of operating the JUNGFRAU detector designed by PSI, a direct detecting x-ray detector, in environments with extreme electromagnetic pulses. The electromagnetic pulse-protective housing is specifically designed for this detector and optimized for pump-probe experiments at the Petawatt High-Energy Laser for Heavy Ion EXperiments (PHELIX) facility at the GSI Helmholtzzentrum für Schwerionenforschung GmbH. The beryllium x-ray entrance window of the protective housing has a high x-ray transmission of 94% at 8 keV. Measurements have shown that the housing simultaneously provides a relative damping of the electromagnetic field on average higher than 1000 in the frequency range of 100 MHz to 5 GHz. The results demonstrate the feasibility of operating digital detectors in experiments where strong electromagnetic pulses are present.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha