Your browser doesn't support javascript.
loading
Quantifying noise limitations of neural network segmentations in high-resolution transmission electron microscopy.
Leth Larsen, Matthew Helmi; Lomholdt, William Bang; Nuñez Valencia, Cuauhtemoc; Hansen, Thomas W; Schiøtz, Jakob.
Afiliação
  • Leth Larsen MH; Computational Atomic-scale Materials Design (CAMD), Department of Physics, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark.
  • Lomholdt WB; National Center for Nano Fabrication and Characterization, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark.
  • Nuñez Valencia C; Computational Atomic-scale Materials Design (CAMD), Department of Physics, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark.
  • Hansen TW; National Center for Nano Fabrication and Characterization, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark.
  • Schiøtz J; Computational Atomic-scale Materials Design (CAMD), Department of Physics, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark. Electronic address: schiotz@fysik.dtu.dk.
Ultramicroscopy ; 253: 113803, 2023 Nov.
Article em En | MEDLINE | ID: mdl-37499574
ABSTRACT
Motivated by the need for low electron dose transmission electron microscopy imaging, we report the optimal frame dose (i.e.e-/Å2) range for object detection and segmentation tasks with neural networks. The MSD-net architecture shows promising abilities over the industry standard U-net architecture in generalising to frame doses below the range included in the training set, for both simulated and experimental images. It also presents a heightened ability to learn from lower dose images. The MSD-net displays mild visibility of a Au nanoparticle at 20-30 e-/Å2, and converges at 200 e-/Å2 where a full segmentation of the nanoparticle is achieved. Between 30 and 200 e-/Å2 object detection applications are still possible. This work also highlights the importance of modelling the modulation transfer function when training with simulated images for applications on images acquired with scintillator based detectors such as the Gatan Oneview camera. A parametric form of the modulation transfer function is applied with varying ranges of parameters, and the effects on low electron dose segmentation is presented.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultramicroscopy Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultramicroscopy Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Dinamarca