Performance of plasma Aß42/40, measured using a fully automated immunoassay, across a broad patient population in identifying amyloid status.
Alzheimers Res Ther
; 15(1): 149, 2023 09 04.
Article
em En
| MEDLINE
| ID: mdl-37667408
ABSTRACT
BACKGROUND:
Plasma biomarkers have emerged as promising screening tools for Alzheimer's disease (AD) because of their potential to detect amyloid ß (Aß) accumulation in the brain. One such candidate is the plasma Aß42/40 ratio (Aß42/40). Unlike previous research that used traditional immunoassay, recent studies that measured plasma Aß42/40 using fully automated platforms reported promising results. However, its utility should be confirmed using a broader patient population, focusing on the potential for early detection.METHODS:
We recruited 174 participants, including healthy controls (HC) and patients with clinical diagnoses of AD, frontotemporal lobar degeneration, dementia with Lewy bodies/Parkinson's disease, mild cognitive impairment (MCI), and others, from a university memory clinic. We examined the performance of plasma Aß42/40, measured using the fully automated high-sensitivity chemiluminescence enzyme (HISCL) immunoassay, in detecting amyloid-positron emission tomography (PET)-derived Aß pathology. We also compared its performance with that of Simoa-based plasma phosphorylated tau at residue 181 (p-tau181), glial fibrillary acidic protein (GFAP), and neurofilament light (NfL).RESULTS:
Using the best cut-off derived from the Youden Index, plasma Aß42/40 yielded an area under the receiver operating characteristic curve (AUC) of 0.949 in distinguishing visually assessed 18F-Florbetaben amyloid PET positivity. The plasma Aß42/40 had a significantly superior AUC than p-tau181, GFAP, and NfL in the 167 participants with measurements for all four biomarkers. Next, we analyzed 99 participants, including only the HC and those with MCI, and discovered that plasma Aß42/40 outperformed the other plasma biomarkers, suggesting its ability to detect early amyloid accumulation. Using the Centiloid scale (CL), Spearman's rank correlation coefficient between plasma Aß42/40 and CL was -0.767. Among the 15 participants falling within the CL values indicative of potential future amyloid accumulation (CL between 13.5 and 35.7), plasma Aß42/40 categorized 61.5% (8/13) as Aß-positive, whereas visual assessment of amyloid PET identified 20% (3/15) as positive.CONCLUSION:
Plasma Aß42/40 measured using the fully automated HISCL platform showed excellent performance in identifying Aß accumulation in the brain in a well-characterized cohort. This equipment may be useful for screening amyloid pathology because it has the potential to detect early amyloid pathology and is readily applied in clinical settings.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Peptídeos beta-Amiloides
/
Doença de Alzheimer
Tipo de estudo:
Prognostic_studies
/
Screening_studies
Limite:
Humans
Idioma:
En
Revista:
Alzheimers Res Ther
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
Japão