Your browser doesn't support javascript.
loading
Impact of age on measurement variability for axial length in myopic children.
Dang, Rebecca M; Watt, Kathleen; Kang, Pauline.
Afiliação
  • Dang RM; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
  • Watt K; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
  • Kang P; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
Clin Exp Optom ; : 1-6, 2023 Sep 06.
Article em En | MEDLINE | ID: mdl-37674270
ABSTRACT
CLINICAL RELEVANCE Axial length is a primary outcome in the management of progressive myopia. However, young children may have difficulty fixating during these measurements compared to older children, which can result in higher measurement variability. This may affect perceived axial length progression, leading to inappropriate management.

BACKGROUND:

This study assessed the impact of patient age on measurement variability for axial length measurements taken with the IOLMaster 700 and IOLMaster 500 in myopic children.

METHODS:

A retrospective review of records was undertaken at a university optometry clinic. Five axial length measurements captured at the same visit were collected with the IOLMaster 700 and IOLMaster 500 for myopic patients ≤16 years. The within-subject standard deviation and R2 were calculated for each instrument to examine the effects of age on instrument variability.

RESULTS:

Data was collected for 51 patients (30 female and 21 male), and the mean age was 10.98 ± 2.77 years. Mean axial length measured with the IOLMaster 700 was longer compared to the IOLMaster 500 (difference -0.02 ± 0.02 mm; p < 0.001). There was no effect of age on within-person variability for the measurement of axial lengths with either instrument, with R2 values of 0.021 (p = 0.305) and 0.13 (p = 0.420) for the IOLMaster 700 and IOLMaster 500, respectively. The within-subject variability of axial measurements with the IOLMaster 700 was significantly lower than that with the IOLMaster 500 (p < 0.001).

CONCLUSION:

Measurement variability of axial length measurements with the IOLMaster 700 and IOLMaster 500 was not dependent on age. However, axial length measurements captured with the IOLMaster 700 were significantly longer and less variable than those with the IOLMaster 500. Eye health care practitioners should be aware of the differences between the two instruments and refrain from using them interchangeably, especially for myopia control where small changes in axial length can affect patient management.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Exp Optom Assunto da revista: OPTOMETRIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Exp Optom Assunto da revista: OPTOMETRIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Austrália