Your browser doesn't support javascript.
loading
Development of a spectrophotometric analytical approach for the measurement of cefdinir in various pharmaceuticals.
Mahmood, Ali Khalil; Sallal, Takleef Dheyab; Al-Janabi, Khalid Waleed S; Luaibi, Hasan Mohammed.
Afiliação
  • Mahmood AK; Department of Chemistry, College of Education for Pure Sciences/Ibn Al-Haitham, University of Baghdad, Baghdad, Iraq.
  • Sallal TD; Ministry of Education, Baghdad, Iraq.
  • Al-Janabi KWS; Department of Chemistry, College of Education for Pure Sciences/Ibn Al-Haitham, University of Baghdad, Baghdad, Iraq.
  • Luaibi HM; Department of Environmental Sciences, College of Energy and Environmental Sciences, Al-Karkh University of Science, Baghdad, Iraq.
J Adv Pharm Technol Res ; 14(3): 263-268, 2023.
Article em En | MEDLINE | ID: mdl-37692006
ABSTRACT
An accurate and sensitive determination procedure has been established for the quantification of cefdinir in pure and pharmacological formulas. The approach was dependent on derivatizing cefdinir with sodium anthraquinone-2-sulfonate (SAS) in an alkaline medium to produce a magenta-colored derivative with a maximum absorbance at 517 nm against the reagent blank. Different factors affecting the interaction of cefdinir with SAS were studied carefully and optimized, such as the buffer value, medium acidity, the duration of hydrolysis, and the reagent percentage. Under optimized conditions, a linear calibration curve with a correlation coefficient of R2 = 0.9995 was obtained over the concentration range of cefdinir 0.5-100 µg/mL. The values of the parameters that represented the sensitivity of the method were satisfactory, i.e., the limit of detection, the limit of quantification, as well as Sandell's sensitivity (л) were 0.1 µg/mL, 0.5 µg/mL, and 0.064 µg/cm2/0.001 Au, respectively. The relative standard deviation was below 1.35%, while the percentage recovery was 99.930%-102.257%. The mole ratio of the colored complex was estimated by following Job's method of continuous variation, which indicated that the cefdinir-SAS ratio was 11. The suggested approach was proven to be adequately accurate, precise, and without interfering with common excipients and additives. Thus, it could be implemented successfully for the standard determination of cefdinir in its pure and pharmaceutical forms.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Adv Pharm Technol Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Iraque

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Adv Pharm Technol Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Iraque