Your browser doesn't support javascript.
loading
LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion.
Yang, Zewen; Zhang, Lu; Liu, Tong; Wu, Haoyu; Tang, Zhiyuan; Fan, Chen; Liu, Xiaolong; Zhang, Zhenxi; Zhao, Hong.
Afiliação
  • Yang Z; State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Zhang L; State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Liu T; State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Wu H; State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Tang Z; Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.
  • Fan C; State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Liu X; Mengchao Hepatobiliary Hospital of Fujian Medical University, The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Fuzhou 350025, China.
  • Zhang Z; Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi'an Jiaotong University, Xi'an 710049, China.
  • Zhao H; State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Biomed Opt Express ; 14(9): 4696-4712, 2023 Sep 01.
Article em En | MEDLINE | ID: mdl-37791256
ABSTRACT
LED array microscopy is a novel computational imaging technique that can achieve two-dimensional (2D) phase imaging and three-dimensional (3D) refractive index imaging with both high resolution and a large field of view. Although its experimental setup is simple, the errors caused by LED array position and light source central wavelength obviously decrease the quality of reconstructed results. To solve this problem, comprehensive error parameters optimized by the phase smoothing criterion are put forward in this paper. The central wavelength error and 3D misalignment model with six freedom degree errors of LED array are considered as the comprehensive error parameters when the spatial positional and optical features of arbitrarily placed LED array are unknown. Phase smoothing criterion is also introduced to the cost function for optimizing comprehensive error parameters to improve the convergence results. Compared with current system correction methods, the simulation and experimental results show that the proposed method in this paper has the best reconstruction accuracy, which can be well applied to an LED array microscope system with unknown positional and optical features of the LED array.