Your browser doesn't support javascript.
loading
Routine Urinary Biochemistry Does Not Accurately Predict Stone Type Nor Recurrence in Kidney Stone Formers: A Multicentre, Multimodel, Externally Validated Machine-Learning Study.
Geraghty, Robert M; Wilson, Ian; Olinger, Eric; Cook, Paul; Troup, Susan; Kennedy, David; Rogers, Alistair; Somani, Bhaskar K; Dhayat, Nasser A; Fuster, Daniel G; Sayer, John A.
Afiliação
  • Geraghty RM; Department of Urology, Freeman Hospital, Newcastle Upon Tyne, United Kingdom.
  • Wilson I; Biosciences Institute, Newcastle University, International Centre for Life, Newcastle Upon Tyne, United Kingdom.
  • Olinger E; Translational and Clinical Institute, Faculty of Medical Sciences, Newcastle University, Newcastle Upon Tyne, United Kingdom.
  • Cook P; Department of Biochemistry, University Hospital Southampton, Southampton, United Kingdom.
  • Troup S; Department of Biochemistry, Queen Elizabeth Hospital, Gateshead, United Kingdom.
  • Kennedy D; Department of Biochemistry, Queen Elizabeth Hospital, Gateshead, United Kingdom.
  • Rogers A; Department of Urology, Freeman Hospital, Newcastle Upon Tyne, United Kingdom.
  • Somani BK; Department of Urology, University Hospital Southampton, Southampton, United Kingdom.
  • Dhayat NA; Department of Nephrology and Hypertension, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Fuster DG; Department of Nephrology and Hypertension, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Sayer JA; Department for Biomedical Research, University of Bern, Bern, Switzerland.
J Endourol ; 37(12): 1295-1304, 2023 12.
Article em En | MEDLINE | ID: mdl-37830220
Objectives: Urinary biochemistry is used to detect and monitor conditions associated with recurrent kidney stones. There are no predictive machine learning (ML) tools for kidney stone type or recurrence. We therefore aimed to build and validate ML models for these outcomes using age, gender, 24-hour urine biochemistry, and stone composition. Materials and Methods: Data from three cohorts were used, Southampton, United Kingdom (n = 3013), Newcastle, United Kingdom (n = 5984), and Bern, Switzerland (n = 794). Of these 3130 had available 24-hour urine biochemistry measurements (calcium, oxalate, urate [Ur], pH, volume), and 1684 had clinical data on kidney stone recurrence. Predictive ML models were built for stone type (n = 5 models) and recurrence (n = 7 models) using the UK data, and externally validated with the Swiss data. Three sets of models were built using complete cases, multiple imputation, and oversampling techniques. Results: For kidney stone type one model (extreme gradient boosting [XGBoost] built using oversampled data) was able to effectively discriminate between calcium oxalate, calcium phosphate, and Ur on both internal and external validation. For stone recurrence, none of the models were able to discriminate between recurrent and nonrecurrent stone formers. Conclusions: Kidney stone recurrence cannot be accurately predicted using modeling tools built using specific 24-hour urinary biochemistry values alone. A single model was able to differentiate between stone types. Further studies to delineate accurate predictive tools should be undertaken using both known and novel risk factors, including radiomics and genomics.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistema Urinário / Cálculos Renais Limite: Humans Idioma: En Revista: J Endourol Assunto da revista: UROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistema Urinário / Cálculos Renais Limite: Humans Idioma: En Revista: J Endourol Assunto da revista: UROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Reino Unido