Your browser doesn't support javascript.
loading
Volatile anticancer drug determination by thermal desorption technique with polydimethylsiloxane-coated macroporous silica adsorbent in gas chromatography-mass spectrometry.
Ueta, Ikuo; Sumiya, Katsunori; Fujimura, Koji; Ariizumi, Yuki; Kikuchi, Ryosuke; Kawata, Keishi; Saito, Yoshihiro.
Afiliação
  • Ueta I; Department of Applied Chemistry, University of Yamanashi, 4-3-11 Takeda, Kofu, 400-8511, Japan. iueta@yamanashi.ac.jp.
  • Sumiya K; Department of Applied Chemistry, University of Yamanashi, 4-3-11 Takeda, Kofu, 400-8511, Japan.
  • Fujimura K; Shinwa Chemical Industries Ltd., 50-2 Kagekatsu, Fushimi, Kyoto, 612-8307, Japan.
  • Ariizumi Y; Department of Applied Chemistry, University of Yamanashi, 4-3-11 Takeda, Kofu, 400-8511, Japan.
  • Kikuchi R; Department of Pharmacy, University of Yamanashi Hospital, 1110 Shimokato, Chuo, 409-3898, Japan.
  • Kawata K; Department of Pharmacy, University of Yamanashi Hospital, 1110 Shimokato, Chuo, 409-3898, Japan.
  • Saito Y; Department of Applied Chemistry and Life Science, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku, Toyohashi, 441-8580, Japan.
Anal Sci ; 40(1): 3-8, 2024 Jan.
Article em En | MEDLINE | ID: mdl-37878142
An analytical method for quantifying the volatile anticancer drugs ifosfamide (IF) and cyclophosphamide (CP) in air was developed on the basis of thermal desorption (TD)-gas chromatography-mass spectrometry. Polydimethylsiloxane-coated macroporous silica was used as the adsorbent. The extraction tube was prepared by packing 0.2 g of adsorbent particles into a glass tube. The extraction and desorption efficiencies of the proposed method were quantitatively investigated in this study. The limits of detection of the proposed method for IF and CP were 3.3 ng L-1 at an air sampling volume of 3.0 L (30 min). The sensitivity of the proposed method was compared with using a Tenax TA packed tube that is widely used as the extraction medium in TD analysis. Finally, detection of IF and CP that evaporated from aqueous standard solution was investigated.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dióxido de Silício / Antineoplásicos Idioma: En Revista: Anal Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dióxido de Silício / Antineoplásicos Idioma: En Revista: Anal Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão